Related Experiment Video
Updated: Nov 27, 2025

Serial Block-Face Scanning Electron Microscopy SBEM for the Study of Dendritic Spines
Published on: October 2, 2021
Ultrastructural comparison of dendritic spine morphology preserved with cryo and chemical fixation
Hiromi Tamada1,2,3,4, Jerome Blanc2, Natalya Korogod2,5
1Laboratory of Sensory Processing, Brain Mind Institute, Faculty of Life Sciences, Ecole Polytechnique Fédérale de Lausanne (EPFL), Lausanne, Switzerland.
Abstract:
Previously, we showed that cryo fixation of adult mouse brain tissue gave a truer representation of brain ultrastructure in comparison with a standard chemical fixation method (Korogod et al., 2015). Extracellular space matched physiological measurements, there were larger numbers of docked vesicles and less glial coverage of synapses and blood capillaries. Here, using the same preservation approaches, we compared the morphology of dendritic spines. We show that the length of the spine and the volume of its head is unchanged; however, the spine neck width is thinner by more than 30% after cryo fixation. In addition, the weak correlation between spine neck width and head volume seen after chemical fixation was not present in cryo-fixed spines. Our data suggest that spine neck geometry is independent of the spine head volume, with cryo fixation showing enhanced spine head compartmentalization and a higher predicted electrical resistance between spine head and parent dendrite.
Related Concept Videos
Cryo-electron Microscopy
Preparation of Samples for Electron Microscopy