Objective:
The use of low-energy electron irradiation for hatching egg disinfection was compared to formaldehyde fumigation.
Material And Methods:
To assess the efficacy, eggshells were examined for bacteria before and after disinfection. During incubation, hatching and fattening of 1400 Ross 308 broilers per group candling data, hatching rate, mortality rate and body mass development were recorded to evaluate the impact on health and performance. Additionally, data from the slaughter house and histological evaluation of organ samples were included in the health screening.
Results:
Regarding the efficacy, irradiation and formaldehyde significantly reduced the number of bacteria compared to non-disinfected eggs. However, no significant difference was recorded between both treatments. The irradiated group performed better than the reference group concerning the number of infertile eggs, early and late dead embryos and fertile eggs. The performance during fattening was nearly identical in both groups, while mortality differed slightly between the irradiated group and the group treated with formaldehyde. Upon slaughter, there were minor variations concerning the distribution of findings between the groups, but the number of anomalies was not higher than reference values suggest.
Conclusion:
In both groups no health problems were observed during rearing and the fattening performance met the targets of the manufacturer Aviagen for the used broiler line Ross 308.
Clinical Relevance:
Lower-energy electron irradiation proves to be an efficient and well-tolerated hatching egg disinfection procedure. Further field trials are necessary to establish low-energy electron irradiation as an alternative to formaldehyde fumigation.
Related Concept Videos
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...