Related Experiment Video
Updated: Nov 27, 2025

The Role of Indocyanine Green Fluorescence in Complex Laparoscopic Cholecystectomy Navigation
Published on: January 31, 2025
Efficacy of Xenon Light With Indocyanine Green for Intersegmental Visibility in Thoracoscopic Segmentectomy
Takuya Matsui1, Yusuke Takahashi2, Takeo Nakada2
1Department of Thoracic Surgery, Aichi Cancer Center Hospital, Nagoya, Japan; Division of Translational Oncoimmunology, Aichi Cancer Center Research Institute, Nagoya, Japan.
Background:
We previously reported useful methods that can be implemented to identify intersegmental boundary lines (IBLs) by using an intravenous indocyanine green (ICG) fluorescence imaging system (ICG-FS) during a thoracoscopic anatomical segmentectomy (TAS). The aim of this study was to evaluate the recently released third-generation ICG-FS that features an emphasizing xenon-light source for IBL identification.
Methods:
We prospectively studied cases involving 106 consecutive patients who underwent TAS. Intraoperatively, we used the third-generation ICG-FS, the conventional ICG methods (CIM) emphasizing xenon-light (CIM-X), and the spectra-A method (SAM) emphasizing xenon-light (SAM-X), for IBL identification. Furthermore, 16 of the 106 patients (15%) could be simultaneously evaluated using old-generation ICG-FSs, CIM, and SAM. All images were completely quantified for illuminance and for three colors, red, green, and blue.
Results:
IBLs were successfully identified in all the patients (100%) with no adverse events. The SAM-X significantly increased the illuminance, especially in the resecting segments, compared to the CIM (39.0 versus 22.2, P < 0.01) and SAM (39.0 versus 29.3, P < 0.01), with enhanced red color compared to the CIM (33.1 versus 21.9, P < 0.01) and SAM (33.1 versus 14.0, P < 0.01). Furthermore, the SAM-X significantly increased the illuminance contrast compared to the CIM-X (34.1 versus 15.3, P < 0.01).
Conclusions:
The present study suggests that the SAM-X potentially provided images with the highest visibility and colorfulness compared to the older generation ICG-FSs or CIM-X. Secure IBL identification can be more easily and safely performed using the SAM-X.