Distribution of pressure on the breast in mammography using flexible and rigid compression plates: implications on
Magnus Dustler1, Daniel Förnvik1, Pontus Timberg1
1Diagnostic Radiology, Department of Translational Medicine, Faculty of Medicine, Lund University, Skåne University Hospital, Malmö, Sweden.
Background:
Breast compression in mammography is important but is a source of discomfort and has been linked to screening non-attendance. Reducing compression has little effect on breast thickness, and likely little effect on image quality, due to force being absorbed in the stiff juxta thoracic area instead of in the central breast.
Purpose:
To investigate whether a flexible compression plate can redistribute force to the central breast and whether this affects perceived pain.
Material And Methods:
Twenty-eight women recalled from mammography screening were compressed with flexible and rigid plates while retaining force and positioning, 15 in the craniocaudal (CC) view and 13 in the mediolateral oblique (MLO) view. Pressure distribution was continuously measured using pressure sensors.
Results:
The flexible plate showed greater mean breast pressure in both views: 2.8 versus 2.3 kPa for CC (confidence interval [CI] = 0.2-0.8) and 1.0 versus 0.5 kPa for MLO (CI = 0.2-0.6). The percentage of applied force distributed to the breast was significantly higher with the flexible plate, both on CC (36% vs. 22%, CI = 1-11) and MLO (30% vs. 14%, CI = 4-13).
Conclusion:
The flexible plate redistributes pressure to the central breast, achieving a better compression, particularly in the MLO view, though much applied force is still applied to the juxta thoracic region.
Related Concept Videos
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Fluid Pressure over Flat Plate of Constant Width
The resultant force...
Radiological Investigation I: X-ray and CT
Fluid Pressure over Curved Plate of Constant Width
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...