Related Experiment Video
Updated: Nov 27, 2025

Synthesis and Purification of Iodoaziridines Involving Quantitative Selection of the Optimal Stationary Phase for Chromatography
Published on: May 16, 2014
Source and drinking water organic and total iodine and correlation with water quality parameters
Rassil Sayess1, Adam M Eyring2, David A Reckhow3
1New York State Water Resources Institute, Department of Biological and Environmental Engineering, Cornell University, Ithaca, NY 14850, United States.
Abstract:
Iodinated disinfection by-products (I-DBPs) have recently emerged as part of the pool of DBPs of public health concern. Due to limitations in measuring individual I-DBPs in a water sample, the surrogate measure of total organic iodine (TOI) is often used to account for the sum of all I-DBPs. In this study, TOI and total iodine (TI) are quantified in raw and treated waters in treatment trains at three sites in the Northeast United States. The occurrence, magnitude, and seasonality of these species was investigated within each sampling train and across the different sites. A regression model was developed to explore how TOI occurrence varies with routinely measured physical and chemical parameters in a water sample. The TOI and TI concentration at the three sites ranged from below the method detection limit to 18 µg/L and from 3 and 18.9 µg/L, respectively. There was substantial inter-monthly variability in TOI without a clear seasonal signal, and the concentration of TOI did not increase upon treatment. The results of the multivariate regression model showed that dissolved organic carbon (DOC), specific UV254 absorbance (SUVA), combined chlorine residual (TCl2), and pH were all significantly related to TOI concentration to varying degrees. A Tobit model was fit to show TOI predictions against observed (measured) TOI values. The model could explain approximately 46% of the variance of TOI concentrations in the treated waters.
More Related Videos
07:26A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
11:19Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity
Published on: March 7, 2016
Related Concept Videos
Quality of Water
Redox Titration: Iodimetry and Iodometry
Testing Water Quality
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Drug Product Performance: In Vitro–In Vivo Correlation
Ionic Strength: Overview