Control and Entropy Analysis of Tip Leakage Flow for Compressor Cascade under Different Clearance Sizes with Endwall
Botao Zhang1, Bo Liu1, Changfu Han1
1School of Power and Energy, Northwestern Polytechnical University, Xi'an 710129, China.
Abstract:
To investigate the influence of the change of tip clearance size on the control effect of the endwall suction, the effects of endwall suction on the aerodynamic performance of the axial compressor cascade were studied numerically. Three tip clearance sizes of 0.5% h, 1.0% h, and 2.0% h (h is the blade height) were mainly considered. The results show that the endwall suction scheme whose coverage range was 8-33% axial chord can reduce the leakage flow and improve the aerodynamic performance by directly influencing the structure of tip leakage vortex. The overall total pressure loss coefficients of the three clearance size schemes at 0° angle of incidence with 0.4 inlet Mach number are reduced by about 10.3%, 10.8%, and 6.0%, respectively, at the suction flow rate of 0.7%. Under the same suction flow rate, the onset position of the tip leakage vortex of the cascade with small clearance is shifted from the 15% of the axial chord length of original to the 48% of the axial chord length, which with large clearance is nearly no changed. The leakage flow rate and the distance from the leakage vortex to the suction slot are the main reasons for the different control effect of the endwall suction under different tip clearance sizes. The difference of the spanwise distribution of flow field parameters may also cause the difference of flow control effect.
Related Concept Videos
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Conservation of Energy in Control Volume
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
Free Jet
Lift
Conservation of Mass in Finite Cotrol Volume
A system is defined as a collection of unchanging contents, and the conservation of mass states that a system's mass is constant.
Control Volume and System Representations
The control volume approach considers a stationary region in space through which fluid flows. This region is bounded by a control surface. For instance, in the case of water...