Background:
Microaspiration of gastric and oropharyngeal secretions is the main causative mechanism of ventilator-associated pneumonia (VAP). Transesophageal echocardiography (TEE) is a routine investigation tool in intensive care unit and could enhance microaspiration. This study aimed at evaluating the impact of TEE on microaspiration and VAP in intubated critically ill adult patients.
Methods:
It is a four-center prospective observational study. Microaspiration biomarkers (pepsin and salivary amylase) concentrations were quantitatively measured on tracheal aspirates drawn before and after TEE. The primary endpoint was the percentage of patients with TEE-associated microaspiration, defined as: (1) ≥ 50% increase in biomarker concentration between pre-TEE and post-TEE samples, and (2) a significant post-TEE biomarker concentration (> 200 μg/L for pepsin and/or > 1685 IU/L for salivary amylase). Secondary endpoints included the development of VAP within three days after TEE and the evolution of tracheal cuff pressure throughout TEE.
Results:
We enrolled 100 patients (35 females), with a median age of 64 (53-72) years. Of the 74 patients analyzed for biomarkers, 17 (23%) got TEE-associated microaspiration. However, overall, pepsin and salivary amylase levels were not significantly different between before and after TEE, with wide interindividual variability. VAP occurred in 19 patients (19%) within 3 days following TEE. VAP patients had a larger tracheal tube size and endured more attempts of TEE probe introduction than their counterparts but showed similar aspiration biomarker concentrations. TEE induced an increase in tracheal cuff pressure, especially during insertion and removal of the probe.
Conclusions:
We could not find any association between TEE-associated microaspiration and the development of VAP during the three days following TEE in intubated critically ill patients. However, our study cannot formally rule out a role for TEE because of the high rate of VAP observed after TEE and the limitations of our methods.
Related Concept Videos
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Acute Respiratory Failure-III