Cortical Bone Assessment Using Ultrasonic Guided Waves: A Reproducibility Study in a Healthy Population
Published on: January 31, 2025
New Markers of Bone Fragility in Hemodialysis Patients: A Monocentric Study
Maroua Slouma1, Takoua Aissaoui1, Maissa Abbes2
1Department of Internal Medicine, Military Hospital, Tunis, Tunisia; University of Tunis El Manar - Tunisia.
Introduction:
Mechanisms underlying bone fragility in patients under dialysis are various. The assessment of bone disorder is not yet codified in these patients. Our study aimed to determine the relationship between the serum fibroblast growth factor 23 (FGF23) level and bone fragility. We also aimed to assess the bone alkaline phosphatase (bAP) to the C-terminal telopeptide of type I (CTX) ratio and the FGF23*bAP product to CTX ratio in patients under hemodialysis.
Methodology:
We conducted a cross-sectional study, including 76 patients under hemodialysis. To assess bone fragility, we measured bAP, CTX, and FGF 23. We calculated the bAP to the CTX ratio (bAP/CTX) and the FGF23*bAP product to the CTX ratio (FGF23*bAP/CTX). We defined bone fragility as the existence of osteoporosis or fragility fractures. Receiver operating characteristic (ROC) curves were evaluated for each biological using the existence of osteoporosis or fragility fracture as the gold standard for bone fragility.
Results:
There were 51 men. The mean age was 53.36 ± 14.27 years. Bone fragility was noted in 25 cases. Patients with osteoporosis had higher FGF*bAP/CTX and bAP/CTX ratios. The ability of the ratio (bAP/CTX) to distinguish patients with osteoporosis from those without osteoporosis was good, with a ROC AUC of 0.707. The optimal ratio cut-off value with the highest accuracy was 9.72. The ability of the ratio (FGF23*bAP/CTX) to distinguish patients with bone fragility was good, with a ROC AUC of 0.701. The optimal ratio cut-off value with the highest accuracy was 1621.89 (sensitivity 60%, specificity 78.4%).
Conclusion:
Our study showed FGF23, FGF23*bAP product to CTX ratio, and the bAP to CTX ratio can be used as markers of bone fragility in hemodialysis patients. Therefore, these noninvasive and relatively inexpensive methods may serve to diagnose bone fragility in patients under hemodialysis.