Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

[Post-Bariatric Body Contouring Surgery: An Analysis of Postoperative Complications and Influencing Factors].

Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...·2025
Same author

Sepsis in Burns-Lessons Learnt from Developments in the Management of Septic Shock.

Medicina (Kaunas, Lithuania)·2022
Same author

A History of Fluid Management-From "One Size Fits All" to an Individualized Fluid Therapy in Burn Resuscitation.

Medicina (Kaunas, Lithuania)·2021
Same author

[Improvement in burn wound care: summary of the AWMF guideline for the treatment of thermal injuries in adults].

Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...·2020
Same author

[Treatment options for burn injuries of the hand - an update].

Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...·2019
Same author

Management of donor site infections in split-thickness skin graft with water-filtered infrared-A (wIRA).

GMS Interdisciplinary plastic and reconstructive surgery DGPW·2018
Same journal

Foundations for the Successful Establishment of a Multidisciplinary Orthoplastic Surgery Team.

Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...·2026
Same journal

Push-Up Techniques Affect Elbows and Shoulders: How Should They Be Used?

Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...·2026
Same journal

[Garbage In, Benchmark Out: A Case for the Courage to Publish Average Results].

Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...·2026
Same journal

Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...·2026
Same journal

Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...·2026
Same journal

Handchirurgie, Mikrochirurgie, plastische Chirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Handchirurgie : Organ der Deutschsprachigen Arbeitsgemeinschaft fur Mikrochirurgie der Peripheren Nerven und Gefasse : Organ der V...·2026
See all related articles

Related Experiment Video

Updated: Nov 26, 2025

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
08:39

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies

Published on: August 25, 2018

26.1K

[Danger in the pocket: explosive e-cigarette].

Philippe Welter1, Seung-Min Ryu, Thomas Pierson

  • 1Sana Klinikum Offenbach GmbH, Klinik für Plastische und Ästhetische Chirurgie, Handchirurgie, Zentrum für Schwerbrandverletzte.

Handchirurgie, Mikrochirurgie, Plastische Chirurgie : Organ Der Deutschsprachigen Arbeitsgemeinschaft Fur Handchirurgie : Organ Der Deutschsprachigen Arbeitsgemeinschaft Fur Mikrochirurgie Der Peripheren Nerven Und Gefasse : Organ Der V
|December 8, 2020
PubMed
Summary
This summary is machine-generated.

Exploding e-cigarettes cause severe burns due to battery "thermal runaway." Injuries affect thighs, genitals, and hands, requiring specialized burn care and highlighting the dangers of device manipulation.

More Related Videos

Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System
10:44

Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System

Published on: May 24, 2017

11.8K
A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
09:30

A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol

Published on: January 18, 2018

8.6K

Related Experiment Videos

Last Updated: Nov 26, 2025

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies
08:39

Generation of Electronic Cigarette Aerosol by a Third-Generation Machine-Vaping Device: Application to Toxicological Studies

Published on: August 25, 2018

26.1K
Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System
10:44

Comparing the Effects of Electronic Cigarette Vapor and Cigarette Smoke in a Novel In Vivo Exposure System

Published on: May 24, 2017

11.8K
A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol
09:30

A Microcontroller Operated Device for the Generation of Liquid Extracts from Conventional Cigarette Smoke and Electronic Cigarette Aerosol

Published on: January 18, 2018

8.6K

Area of Science:

  • Trauma Surgery
  • Burn Care
  • Materials Science

Background:

  • E-cigarette popularity has surged in Europe over the past decade.
  • Beyond potential lung damage, e-cigarette battery explosions pose a significant injury risk.
  • Users are often unaware of the inherent dangers associated with e-cigarette batteries.

Purpose of the Study:

  • To describe the cause, extent, and treatment of burn injuries resulting from e-cigarette battery explosions.
  • To analyze the specific injury patterns and patient demographics associated with these incidents.
  • To emphasize the need for specialized care and safety precautions for e-cigarette use.

Main Methods:

  • A retrospective case series of four patients treated for burns from exploded e-cigarettes.
  • Data collected between February and July 2019 at a German burn center.
  • Analysis of injury causes, severity, affected body regions, and treatment outcomes.

Main Results:

  • Explosions were caused by battery "thermal runaway" (rapid discharge).
  • All four patients were male, with an average age of 37.
  • Burns ranged from superficial (Grade I) to deep (Grade IIb), averaging 3% Total Body Surface Area (TBSA), primarily on thighs, genitals, and hands.
  • Treatment included conservative, surgical (alloplastic covers, skin grafts), and in one case, self-discharge.
  • Average hospital stay for three patients was 15.6 days.

Conclusions:

  • E-cigarette explosion burns are a rare but severe injury requiring specialized burn center treatment.
  • Injuries involve thermal burns, chemical necrosis from electrolytes, and foreign body contamination.
  • Specialized initial management and fire suppression are necessary.
  • Safe handling of CE-certified devices and prohibition of manipulation are crucial to prevent these dangerous incidents.