Related Experiment Video
Updated: Aug 12, 2026

Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Resin corrosion cast in experimental evaluation of femoral microanastomosis
V Travers1, R R Kanaujia, Y Ikuta
1Service de Chirurgie Orthopédique, Hôpital Saint-Antoine, Paris.
Abstract:
In order to obtain more information about the site of microvascular anastomosis, the authors used the methylmethacrylate resin corrosion casts. 80 microvascular anastomoses were performed in Wistar albino rats and divided into two groups: in the Group 1 (40 anastomoses), the resin was injected into the vessel whereas in Group 2, the tissues were prepared without injecting resin. Both groups were compared under the scanning electron microscope (SEM). The SEM preparation was easier in the Group 1 and the artefacts were significantly reduced. The anastomotic site was better appreciated in Group 1 in three-dimensional views. The resin corrosion cast is a promising technique for the evaluation of the microvascular anastomosis.