Evaluation of Crohn Disease Activity Using a Potential Abbreviated MRE Protocol Consisting of Balanced Steady-State Free Precession MRI Only Versus Full-Protocol MRE
Related Experiment Video
Updated: Nov 26, 2025

Quantitative Magnetic Resonance Imaging of Skeletal Muscle Disease
Published on: December 18, 2016
Kartik S Jhaveri1, Soodeh Sagheb1, Luis Guimaraes1
1Joint Department of Medical Imaging, University Health Network, Mount Sinai Hospital, and Women's College Hospital, University of Toronto, 610 University Ave, 3-957, Toronto, ON M5G 2M9, Canada.
Abstract:
OBJECTIVE. The purpose of the present study was to compare the diagnostic performance of an abbreviated MR enterography (MRE) protocol consisting of balanced steady-state free-precession (b-SSFP) imaging only versus standard full-protocol MRE for the evaluation of Crohn disease activity. MATERIALS AND METHODS. This single-center retrospective study included 112 patients with Crohn disease (66 women and 46 men; age range, 18-84 years) who underwent MRE between January 2017 and March 2018. Utilizing binary and 5-point Likert confidence scales, two blinded readers independently interpreted and scored disease activity on b-SSFP sequences only and on full-protocol MRE images. Interreader and intrareader agreement on confidence regarding disease activity were calculated using weighted kappa indexes. Correlation between MRE findings of Crohn disease and the Harvey-Bradshaw index was also performed. RESULTS. Perfect intrareader agreement and strong interreader agreement on disease activity were observed (intrareader agreement: κ = 0.97, 0.96, and 0.96 for reader A, reader B, and both readers combined; interreader agreement: κ = 0.82 for b-SSFP imaging only and κ = 0.81 for MRE). For detecting active Crohn disease, b-SSFP sequences had a sensitivity and specificity of 97% and 100%, respectively, for reader A and 98% and 86%, respectively, for reader B. Strong-to-perfect intrareader agreement was achieved between b-SSFP imaging only and MRE for identification of penetrating disease (κ = 0.80 and 0.97) and stenosing disease (κ = 0.87 and 0.95). Perfect intrareader agreement was also obtained between b-SSFP imaging only and MRE for detecting abnormal bowel segments (κ = 0.91 for reader A; κ = 0.98 for reader B). Weak agreement was noted between both b-SSFP imaging only and MRE versus the Harvey-Bradshaw index (κ = 0.08 of reader A; κ = 0.04 for reader B). CONCLUSION. Robust agreement was observed between b-SSFP imaging only and full-protocol MRE for the assessment of Crohn disease activity and complications. An abbreviated MRE protocol that exclusively uses b-SSFP sequences appears feasible and has significant implications for health care resources.
Insights
An abbreviated MR enterography (MRE) protocol using only balanced steady-state free-precession (b-SSFP) sequences shows high diagnostic performance for Crohn disease activity. This abbreviated MRE approach is feasible and resource-efficient.
Area of Science:
- Gastroenterology
- Radiology
- Medical Imaging
Background:
- Crohn disease requires accurate assessment of disease activity and complications.
- Magnetic Resonance Enterography (MRE) is a key imaging modality for Crohn disease.
- Standard MRE protocols can be time-consuming and resource-intensive.
Purpose of the Study:
- To compare the diagnostic performance of an abbreviated MRE protocol (b-SSFP sequences only) versus a standard full-protocol MRE.
- To evaluate the feasibility of using b-SSFP sequences alone for assessing Crohn disease activity.
- To determine the implications for healthcare resource utilization.
Main Methods:
- Retrospective study of 112 patients with Crohn disease.
- Two blinded readers independently scored disease activity using b-SSFP sequences only and full-protocol MRE.
- Interreader and intrareader agreement assessed using weighted kappa indexes.
- Correlation with Harvey-Bradshaw index performed.
Main Results:
- High diagnostic performance for active Crohn disease with b-SSFP sequences (sensitivity 97-98%, specificity 86-100%).
- Strong-to-perfect intrareader agreement between abbreviated and full MRE for disease activity and complications (κ = 0.80-0.98).
- Weak agreement noted between MRE findings and the Harvey-Bradshaw index (κ < 0.1).
Conclusions:
- An abbreviated MRE protocol using only b-SSFP sequences demonstrates robust agreement with full-protocol MRE for Crohn disease assessment.
- This abbreviated protocol is feasible and potentially reduces healthcare resource utilization.
- b-SSFP sequences alone are effective for evaluating Crohn disease activity and complications.
More Related Videos
15:49Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
09:18Measurements of Motor Function and Other Clinical Outcome Parameters in Ambulant Children with Duchenne Muscular Dystrophy
Published on: January 12, 2019
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Magnetic Resonance Imaging
Imaging Studies IV: Magnetic Resonance Imaging