Machine learning tools to estimate the severity of matrix effects and predict analyte recovery in inductively coupled
Jake A Carter1, Logan M O'Brien1, Tina Harville2
1Department of Chemistry, Wake Forest University, Salem Hall, Box 7486, Winston-Salem, NC, 27109, USA.
Abstract:
Supervised and unsupervised machine learning methods are used to evaluate matrix effects caused by carbon and easily ionizable elements (EIEs) on analytical signals of inductively coupled plasma optical emission spectrometry (ICP OES). A simple experimental approach was used to produce a series of synthetic solutions with varying levels of matrix complexity. Analytical lines (n = 29), with total line energies (Esum) in the 5.0-15.5 eV range, and non-analyte signals (n = 24) were simultaneously monitored throughout the study. Labeled (supervised learning) and unlabeled (unsupervised learning) data on normalized non-analyte signals (from plasma species) were used to train machine learning models to characterize matrix effect severity and predict analyte recoveries. Dimension reduction techniques, including principal component analysis, uniform manifold approximation and projection and t-distributed stochastic neighborhood embedding, were able to provide visual and quantitative representations that correlated well with observed matrix effects on low-energy atomic and high-energy ionic emission lines. Predictive models, including partial least squares regression and generalized linear models fit with the elastic net penalty, were tuned to estimate analyte recovery error when using the external standard calibration method (EC). The best predictive results were found for high-energy ionic analytical lines, e.g. Zn II 202.548 nm (Esum = 15.5 eV), with accuracy and R2 of 0.970 and 0.856, respectively. Two certified reference materials (CRMs) were used for method validation. The strategy described here may be used for flagging compromising matrix effects, and complement method validation based on addition/recovery experiments and CRMs analyses. Because the data analysis workflows feature signals from plasma-based species, there is potential for developing instrument software capable of alerting users in real time (i.e. before data processing) of inaccurate results when using EC.
More Related Videos
09:49Investigation of Microbial Cooperation via Imaging Mass Spectrometry Analysis of Bacterial Colonies Grown on Agar and in Tissue During Infection
Published on: November 18, 2022
06:56Characterization of Synthetic Polymers via Matrix Assisted Laser Desorption Ionization Time of Flight MALDI-TOF Mass Spectrometry
Published on: June 10, 2018
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Atomic Emission Spectroscopy: Instrumentation