Related Experiment Video
Updated: Nov 26, 2025

A Study of the Complexation of MercuryII with Dicysteinyl Tetrapeptides by Electrospray Ionization Mass Spectrometry
Published on: January 8, 2016
Comparison of Primary Laser Spectroscopy and Mass Spectrometry Methods for Measuring Mass Concentration of Gaseous
Abneesh Srivastava1, Stephen E Long1, James E Norris1
1Chemical Sciences Division, National Institute of Standards and Technology, 100 Bureau Drive, Gaithersburg, Maryland 20899-8393, United States.
Abstract:
We present a direct comparison between two independent methods for the measurement of gaseous elemental mercury (GEM) mass concentration: isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICP-MS) and laser absorption spectroscopy (LAS). The former technique combined with passive sorbent tube sampling is currently the primary method at NIST for mercury gas standards traceability to the International System of Units (SI). This traceability is achieved via measurements on a mercury-containing reference material. The latter technique has been recently developed at NIST and involves real-time measurements of light attenuation caused by GEM, with SI traceability based in part on the known spontaneous emission lifetime of the probed 6 1S0-6 3P1 intercombination transition of elemental mercury (Hg0). Using a steady-flow Hg0-in-air generator to produce samples measured by both methods, we use LAS to measure the sample gas and in parallel we collect the Hg0 on sorbent tubes to be subsequently analyzed using ID-CV-ICP-MS. Over the examined mass concentration range (41 microg/m3 to 287 microg/m3 Hg0 in air), the relative disagreement between the two approaches ranged from (1.0 to 1.8)%. The relative combined standard uncertainty on average is 0.4% and 0.9%, for the LAS and MS methods, respectively. Our comparison studies help validate the accuracy of the ID-CV-ICP-MS primary method as well as establish the LAS technique as an attractive alternative primary method for SI-traceable measurements of GEM.
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Mass Spectrometers
High-Resolution Mass Spectrometry (HRMS)
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Analyzers: Overview
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview

