Related Experiment Video
Updated: Nov 26, 2025

A Novel Technique for Generating and Observing Chemiluminescence in a Biological Setting
Published on: March 9, 2017
A novel luminol chemiluminescence system induced by black phosphorus quantum dots for cobalt (II) detection
Hongdan Li1, Jiawei Wang1, Jianxiu Du1
1Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710119, China.
Abstract:
Black phosphorus quantum dots (BP QDs) were prepared through a solvothermal exfoliation method in alkaline N-methyl-2-pyrrolidinone. The BP QDs induce distinct chemiluminescence (CL) of alkaline luminol directly. A possible reaction mechanism is proposed by the study of CL spectrum, ultraviolet-visible absorption spectra, electron paramagnetic resonance spectra as well as radical scavenging experiments. The presence of BP QDs significantly increases generation of active oxygen species, which oxidize luminol and lead to intense CL emission at 425 nm. The reaction of luminol with BP QDs are specifically catalyzed by cobalt (II) ion, this presents a sensitive CL method for cobalt (II) ion. A linear response range extends from 2.5 to 2000.0 pmol/L cobalt (II) ion and a detection limit of 0.7 pmol/L (3sb) is acquired. The method displays a good precision approved by a relative standard deviation of 1.9% at 100.0 pmol/L cobalt (II) ion solution (n = 11). A preliminary application of the method was conducted by successful determination of cobalt amount in silica gel and rain water samples.
More Related Videos
07:13Author Spotlight: High-Quality Quantum Dot Nanobeads for Sensitive Fluorescent Lateral Flow Immunoassays
Published on: June 28, 2024
08:40Synthesis of Metal Nanoparticles Supported on Carbon Nanotube with Doped Co and N Atoms and its Catalytic Applications in Hydrogen Production
Published on: December 6, 2021
Related Concept Videos
Photoluminescence: Applications
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...