A chip-based 128-channel potentiostat for high-throughput studies of bioelectrochemical systems: Optimal electrode
Tom R Molderez1, Antonin Prévoteau2, Frederik Ceyssens3
1MICAS, KU Leuven, Kasteelpark Arenberg 10, 3001 Leuven, Belgium; Center for Microbial Ecology and Technology (CMET), Ghent University, Coupure Links 653, 9000 Ghent, Belgium.
Abstract:
The presence of microorganisms performing extracellular electron transfer has been established in many environments. Research to determine their role is moving slowly due to the high cost of potentiostats and the variance of data with small number of replicates. Here, we present a 128-channel potentiostat, connected to a 128 gold electrode array. Whereas the system is able to perform simultaneously 128 (bio)electrochemical measurements with an independent electrical signal input, the present manufacturing of the array limited the number of effective channels for this study to 77. We assessed the impact of 11 electrode potentials ranging from -0.45V to +0.2V vs. Ag/AgCl (7 replicates per potential) on the growth and electrochemical characteristics of anodic electroactive biofilms (EABs) formed by acetate-fed microbial communities. After 7 days of growth, maximum current was reached for electrodes poised at -0.3V, closely followed by -0.25V and -0.1V to +0.1V, a range well-fitting the midpoint potential of minerals naturally reduced by electroactive bacteria such as Geobacter Sulfurreducens. There was no significant difference in apparent midpoint potential of the EABs (-0.35V), suggesting that the mechanism of heterogeneous electron transfer was not affected by the electrode potential. The EABs poised below current plateau potential (≤-0.3V) exhibited slower growth but higher charge transfer parameters. The high-throughput and high reproducibility provided by the array may have a major facilitating impact on the field of electromicrobiology. Key aspects to improve are data processing algorithms to deal with the vast amount of generated data, and manufacturing of the electrode array itself.
Related Concept Videos
Potentiometry: Membrane Electrodes
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometry: Overview
Patch Clamp
In this method, a glass micropipette containing electrolyte solution is tightly sealed against a small portion of the cell membrane. As a result, a patch of the cell...