Factors Associated With Radiation Pneumonitis in Patients Receiving Electron Boost Radiation for Breast-Conserving
Wataru Kawakami1, Shigeyuki Takamatsu1,2, Masashi Taka2,3
1Department of Radiation Oncology, Public Central Hospital of Matto Ishikawa, Ishikawa, Japan.
Purpose:
This study aimed to investigate risk factors for radiation pneumonitis (RP) caused by electron beam (EB) boost irradiation during breast-conserving therapy.
Methods And Materials:
This single-institution retrospective study included patients with breast cancer treated with breast-conserving therapy from 2013 to 2019. Radiation therapy comprised whole-breast irradiation with a dose of 50 Gy and 10 Gy EB boost dose to the tumor bed. EB energies were 4, 6, 9, 12, and 15 MeV. The lung volume receiving ≥1.25 Gy (V1.25) was calculated and considered because the EB energies have a short range. All patients underwent computed tomography and positron emission tomography/computed tomography within 1 year of irradiation. Imaging evaluation was based on the Common Terminology Criteria for Adverse Events, version 5.0.
Results:
Overall, 105 patients (median age, 62 years; range, 33-85) were included for analysis with a median follow-up period of 5 months. Average area of EB boost irradiation was 72 cm2 (range, 36-196). Grade 1 RP developed in the EB irradiation field in 22 (20.6%) patients; grade 2 RP developed in 1 (0.93%) patient. Even in patients with central lung distance (CLD) ≥1.8 cm, a positive correlation was found between RP and both energy (r = 0.36; P = .005) and V1.25 (r = 0.26; P = .04). No correlation was found between RP and irradiation field size (P = .47). The EB energy and V1.25 cutoff values were 12 MeV and 24 cm3, respectively.
Conclusions:
CLD of ≥1.8 cm, EB energy of ≥12 MeV, and V1.25 of ≥24 cm3 were risk factors associated with RP. Although the frequency of severe RP was not high, patients receiving high-energy electron treatment and those with a large CLD should be closely monitored.
More Related Videos
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pneumothorax-II
Clinical Manifestations:
Pneumonia III: Complications and Assessment
Pneumonia I: Introduction
Risk Factors
Various factors influence the likelihood of developing pneumonia. Age plays a crucial role, with infants, children under two, and individuals over 65 at increased risk due to their...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Pneumonia V: Nursing management and Prevention
The nurse must practice strict medical asepsis and adhere to infection control guidelines to minimize healthcare-associated infections.
Enhance airway patency
Position the patient correctly to facilitate drainage of the affected lung segments. Manual or mechanical percussion and vibration can also be employed....