Benjamin Longère1, Marc-Henry Chavent2, Augustin Coisne3
1Department of Cardiovascular Radiology, Institut Cœur-Poumon, CHU de Lille, Boulevard du Pr Jules Leclercq, 59037 Lille Cedex, France; INSERM UMR 1011, Institut Pasteur de Lille, EGID (European Genomic Institute for Diabetes), FR3508, Univ. Lille, 59000 Lille, France.
Purpose:
To evaluate the reliability of a real-time compressed sensing (CS) cine sequence for the detection of left ventricular wall motion disorders after myocardial infarction in comparison with the reference steady-state free precession cine sequence.
Materials And Methods:
One hundred consecutive adult patients referred for either initial work-up or follow-up by cardiac magnetic resonance (CMR) in the context of myocardial infarction were prospectively included. There were 77 men and 23 women with a mean age of 63.12±11.3 (SD) years (range: 29-89 years). Each patient underwent the reference segmented multi-breath-hold steady-state free precession cine sequence including one short-axis stack and both vertical and horizontal long-axis slices (SSFPref) and the CS real-time single-breath-hold evaluated sequence (CSrt) providing the same slices. Wall motion disorders were independently and blindly assessed with both sequences by two radiologists, using the American Heart Association left ventricle segmentation. Paired Wilcoxon signed-rank test was used to search for differences in wall motion disorders conspicuity between both sequences and receiver operating characteristic curve (ROC) analysis was performed to assess the diagnosis performance of CSrt sequence using SSFPref as the reference method.
Results:
Each patient had at least one cardiac segment with wall motion abnormality on SSFPref and CSrt images. The 1700 segments analyzed with SSFPref were classified as normokinetic (360/1700; 21.2%), hypokinetic (783/1700; 46.1%), akinetic (526/1700; 30.9%) or dyskinetic (31/1700; 1.8%). Sensitivity and specificity of the CS sequence were 99.6% (95% CI: 99.1-99.9%) and 99.7% (95% CI: 98.5-100%), respectively. Area under ROC of CSrt diagnosis performance was 0.997 (95% CI: 0.993-0.999).
Conclusion:
CS real-time cine imaging significantly reduces acquisition time without compromising the conspicuity of left ventricular -wall motion disorders in the context of myocardial infarction.
Related Concept Videos
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Acute Coronary Syndrome III: Diagnostic Studies