Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Protein Dynamics in Living Cells01:19

Protein Dynamics in Living Cells

2.5K
Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
2.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Scout-based Multi-Echo NAvigator (SMENA) for high temporal resolution motion and B <sub>0</sub> estimation and correction: applications to multi-echo GRE and EPTI.

bioRxiv : the preprint server for biology·2026
Same author

Accelerating MRI With Longitudinally-Informed Latent Posterior Sampling.

Magnetic resonance in medicine·2026
Same author

A Dynamic Shim Approach for Correcting Eddy Current Effects in Diffusion-Prepared MRI Acquisition Using a Multi-Coil AC/DC Shim-Array.

Magnetic resonance in medicine·2026
Same author

In Vivo Meso-Scale Whole-Brain Quantitative Imaging With Tailored MRF on the NexGen 7T Scanner.

Magnetic resonance in medicine·2025
Same author

The Effect of Voxel Volume and Voxel Shape on Cardiac Diffusion Tensor Imaging Metrics.

Magnetic resonance in medicine·2025
Same author

Micron-resolution fiber mapping in histology independent of sample preparation.

Nature communications·2025

Related Experiment Video

Updated: Nov 26, 2025

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.6K

Diffusion-PEPTIDE: Distortion- and blurring-free diffusion imaging with self-navigated motion-correction and

Merlin J Fair1,2, Congyu Liao1,2, Mary Kate Manhard1,2

  • 1Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, Massachusetts, USA.

Magnetic Resonance in Medicine
|December 14, 2020
PubMed
Summary

This study introduces a new magnetic resonance imaging method that combines diffusion measurements with relaxometry. By replacing standard echo-based imaging, this technique eliminates common image distortions and blurring. It also corrects for patient movement during scans, allowing for high-quality brain imaging and the simultaneous calculation of tissue properties like T2 and T2* relaxation times.

Keywords:
blurring-freediffusion imagingdiffusion-relaxometrydistortion-freemotion-robustmulti-shotneuroimagingrelaxometryspin-echoartifact reduction

Frequently Asked Questions

More Related Videos

Image Processing Protocol for the Analysis of the Diffusion and Cluster Size of Membrane Receptors by Fluorescence Microscopy
12:15

Image Processing Protocol for the Analysis of the Diffusion and Cluster Size of Membrane Receptors by Fluorescence Microscopy

Published on: April 9, 2019

9.0K
From Fast Fluorescence Imaging to Molecular Diffusion Law on Live Cell Membranes in a Commercial Microscope
15:10

From Fast Fluorescence Imaging to Molecular Diffusion Law on Live Cell Membranes in a Commercial Microscope

Published on: October 9, 2014

11.7K

Related Experiment Videos

Last Updated: Nov 26, 2025

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring
17:16

Registered Bioimaging of Nanomaterials for Diagnostic and Therapeutic Monitoring

Published on: December 9, 2010

10.6K
Image Processing Protocol for the Analysis of the Diffusion and Cluster Size of Membrane Receptors by Fluorescence Microscopy
12:15

Image Processing Protocol for the Analysis of the Diffusion and Cluster Size of Membrane Receptors by Fluorescence Microscopy

Published on: April 9, 2019

9.0K
From Fast Fluorescence Imaging to Molecular Diffusion Law on Live Cell Membranes in a Commercial Microscope
15:10

From Fast Fluorescence Imaging to Molecular Diffusion Law on Live Cell Membranes in a Commercial Microscope

Published on: October 9, 2014

11.7K

Area of Science:

  • Medical imaging informatics within Diffusion-PEPTIDE research
  • Radiological physics and signal processing

Background:

Standard magnetic resonance imaging often suffers from significant geometric distortions and blurring when using conventional echo planar sequences. These artifacts frequently compromise the diagnostic accuracy of diffusion-weighted scans in clinical settings. Researchers have long sought methods to mitigate these spatial inaccuracies while maintaining high temporal resolution. No prior work had resolved the trade-off between rapid acquisition and image fidelity in diffusion-weighted imaging. Existing approaches to motion correction often require external tracking hardware or complex post-processing pipelines. This gap motivated the development of self-navigated techniques that integrate directly into the acquisition sequence. Previous studies highlighted the sensitivity of diffusion metrics to patient movement and phase inconsistencies. That uncertainty drove the need for a robust framework capable of handling rotational motion during data collection.

Purpose Of The Study:

The primary aim of this work is to implement a time-resolved relaxometry technique into a diffusion acquisition sequence. This integration seeks to provide self-navigated imaging that remains free from common distortions and blurring. The researchers intend to create a robust method that maintains high fidelity despite potential patient movement during the scanning process. They also aim to enable the simultaneous generation of T2 and T2* maps alongside standard diffusion parameters. This effort addresses the limitations of conventional echo planar imaging, which often suffers from significant spatial inaccuracies. The study explores the potential of these rich datasets for advanced multi-compartment modeling of tissue microstructure. By validating the approach with both in vivo brain protocols and phantom models, the authors establish the utility of their sequence. This motivation drives the development of a more reliable and informative diagnostic tool for clinical neuroimaging applications.

Main Methods:

The investigators implemented a time-resolved relaxometry readout directly into a spin-echo diffusion acquisition framework. They evaluated the performance of this sequence using two distinct in vivo brain protocols with varying spatial resolutions. The team deliberately introduced rotational motion during experiments to assess the resilience of the reconstruction against phase variations. They calculated T2 and T2* parameter maps alongside standard diffusion metrics from the acquired data. To test the utility for multi-compartment modeling, the researchers scanned a gadolinium-doped asparagus phantom. This phantom provided a controlled environment with known relaxation and diffusion properties across different orientations. The analysis involved comparing the reconstructed images against those produced by conventional echo planar imaging methods. Finally, the researchers quantified the impact of motion on image quality to confirm the effectiveness of their self-navigated approach.

Main Results:

The primary finding demonstrates that the technique produces high-quality images free from the distortions typically seen in echo planar sequences. The reconstructions successfully avoided resolution losses exceeding 100% compared to standard acquisition methods. The approach showed remarkable tolerance to nearly 30 degrees of rotational motion during the deliberate corruption experiments. In the two-compartment phantom, the researchers observed expected variations in T2 values as a function of diffusion direction with a significance level of P < .01. The brain protocols yielded successful parameter maps in 20 minutes for high-resolution scans and 3.4 minutes for faster acquisitions. These results confirm that the method provides reliable diffusion and relaxometry data simultaneously. The data quality remained consistent across all tested diffusion directions and protocols. This performance suggests that the sequence effectively mitigates phase inconsistencies without requiring external tracking hardware.

Conclusions:

The authors propose that their novel sequence successfully eliminates common spatial distortions found in traditional echo planar imaging. They report that the technique maintains high image quality even when subjects undergo significant rotational movement. The study demonstrates that simultaneous mapping of relaxation parameters and diffusion properties is feasible within standard clinical timeframes. Researchers suggest that the integration of self-navigation provides a reliable solution for motion-prone environments. The findings indicate that the method effectively captures complex tissue properties in multi-compartment phantom models. The authors conclude that this approach offers a versatile platform for advanced diffusion-relaxometry investigations. They highlight the potential for future applications in characterizing tissue microstructure through multi-compartment modeling. This work establishes a foundation for more robust and informative neuroimaging protocols in diverse patient populations.

The researchers propose that the mechanism relies on integrating a time-resolved relaxometry readout into a spin-echo diffusion acquisition. This configuration enables the reconstruction of a time-series of images, which effectively bypasses the spatial distortions typically associated with conventional echo planar imaging sequences.

The authors utilize a gadolinium-doped asparagus phantom to validate the technique. This specific model contains two distinct compartments with varying relaxation parameters and diffusion orientation properties, allowing for the exploration of T2 relaxation variations across different diffusion directions.

The authors state that the spin-echo diffusion acquisition is necessary to enable the reconstruction of time-series images. This specific sequence architecture allows for the simultaneous calculation of T2 and T2* maps while maintaining robustness against shot-to-shot phase variations during the scanning process.

The researchers employ diffusion-weighted images to calculate parameter maps. These datasets serve as the foundation for multi-compartment modeling, enabling the extraction of rich information regarding tissue microstructure that would otherwise be obscured by the artifacts present in standard echo planar imaging.

The study measures the tolerance to rotational motion, finding that the technique remains effective even with nearly 30 degrees of rotation. Additionally, the researchers observe significant variations in T2 values as a function of diffusion direction within the phantom, with a statistical significance of P < .01.

The researchers propose that this method offers significant potential for future applications in diffusion-relaxometry multi-compartment modeling. They suggest that the ability to provide highly robust data will facilitate more accurate characterization of tissue properties in complex clinical scenarios.