Concordance testing between Powerplex ESI 16 Fast System and VeriFiler Express
Hagit Schayek1, Ortal Waiskopf2, Ksenia Rashkovski1
1DNA Database Laboratory, Division of Identification and Forensic Science (DIFS), Israel Police, Jerusalem, Israel.
Abstract:
DNA profiles generated by different STR kits may show different alleles for identical amplified loci. This well-known phenomenon affects the smooth transition of data generated by new STR kits to a database or casework laboratory or cross-laboratory comparison of STR profiles. As in other DNA databases throughout the world, it has become clear that the number of the analyzed loci should be expanded for a variety of reasons, such as partial profiles resulting from low copy-number DNA template or degraded samples, working with mixtures or when prevalence of familial inbreeding. In the course of introducing a new STR kit, VeriFiler™ Express (Applied Biosystems, Foster City, CA, USA), we compared genotyping data of 1568 samples amplified by the VeriFiler™ Express with the data generated on the same samples by the Powerplex™ ESI FAST (Promega, Madison WI, USA) kit. Discordance was noted in 20 samples (1.27%), 14 (0.89%) of them showing allele dropout mismatch and six (0.38%) showing an additional fixed-size third allele. These rates are well above the reported rates of 0.4% for this kit. Since correct genotyping and accurate consistent allele assignment is of paramount importance, it seems timely to recommend for DNA laboratories and genetic-match search systems to take these possible inconsistencies into account.
More Related Videos
07:02A Computerized Test Battery to Study Pharmacodynamic Effects on the Central Nervous System of Cholinergic Drugs in Early Phase Drug Development
Published on: February 11, 2019
11:08Proofreading and DNA Repair Assay Using Single Nucleotide Extension and MALDI-TOF Mass Spectrometry Analysis
Published on: June 19, 2018
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Compacting Factor test
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
Capillary Electrophoresis: Instrumentation
Detection of Gross Error: The Q Test
Power Factor Correction
Fisher's Exact Test