Purpose:
The purpose of the study was to examine the impact of the first wave of COVID-19 on National Health Service (NHS) 18F-fluorodeoxyglucose positron emission tomography computed tomography (FDG PET-CT) scanning activity across England.
Methods:
Monthly FDG PET-CT scanning activity was collected from 41/48 NHS England provider sites. Data from 31/41 sites were stratified by nononcology/oncology, cancer type, with lung cancer and lymphoma split into specific indications, turn-around times and delays due to radiotracer.
Results:
In April and May 2020, a 32 and 31% decrease in activity was observed, a larger decrease for noncancer compared with cancer FDG PET-CT. In June 2020, activity started to recover with 6% fewer scans recorded compared with June 2019. Of the six most common indications, lung and oesophageal cancer had the largest decrease in activity and slowest recovery. Lymphoma and melanoma showed the smallest decrease and fastest recovery. Lung cancer scans for initial diagnosis/staging saw the largest fall and slowest recovery compared with scans for known lung cancer. There was no percentage increase in overall turn-around time compared with the same months in 2019, and no increase in turn-around time of more than 7 working days due to FDG supply during April and May 2020 compared with the 3 previous months.
Conclusions:
There is no correlation between FDG PET-CT activity (fall and recovery) in England and the ability to provide the service by NHS England. It most likely reflects a combination of changes in health-seeking behaviour, NHS health policy and a decrease in the use of investigations that carry a high risk of COVID-19 transmission.
Related Concept Videos
Current Trends in Nursing II
Issues And Trends In Healthcare Delivery System
Cost Containment
Payment for healthcare services has historically promoted adoption of costly and often unnecessary or inefficient...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care