Contribution of Bowman layer to corneal biomechanics
Emilio A Torres-Netto1, Farhad Hafezi, Bogdan Spiru
1From the Laboratory of Cell Biology, Center for Applied Biotechnology and Molecular Medicine, University of Zurich, Zurich, Switzerland (Torres-Netto, F. Hafezi, Gilardoni); Department of Ophthalmology and Visual Sciences, Paulista School of Medicine, Federal University of Sao Paulo, Sao Paulo, Brazil (Torres-Netto, Gomes); ELZA Institute, Dietikon/Zurich, Switzerland (Torres-Netto, F. Hafezi, Gilardoni); Faculty of Medicine, University of Geneva, Geneva, Switzerland (Torres-Netto, F. Hafezi); Department of Ophthalmology, University of Southern California, Los Angeles, California (F. Hafezi, N. Hafezi); Department of Ophthalmology, Wenzhou Medical University, Wenzhou, China (F. Hafezi); Department of Ophthalmology, Phillips University of Marburg, Marburg, Germany (Spiru, Sekundo); Cole Eye Institute, Cleveland Clinic, Cleveland, Ohio (Randleman); Computer Vision Laboratory, Swiss Federal Institute of Technology, Zurich, Switzerland (Kling).
Purpose:
To compare the elastic modulus of thin corneal lamellas using 2D stress-strain extensometry in healthy ex vivo human corneal lamellas with or without the presence of Bowman layer.
Setting:
Center for Applied Biotechnology and Molecular Medicine, University of Zurich, Switzerland; ELZA Institute, Dietikon, Switzerland; Department of Ophthalmology, Philipps University of Marburg, Germany.
Design:
Prospective experimental laboratory study.
Methods:
Healthy human corneas were stripped of Descemet membrane and the endothelium for Descemet membrane endothelial keratoplasty. After epithelium removal, corneas were divided into 2 groups. In Group 1, Bowman layer was ablated with an excimer laser (20 μm thick, 10 mm). In Group 2, Bowman layer was left intact. Then, a lamella was cut from the anterior cornea with an automated microkeratome. Elastic and viscoelastic material properties were analyzed by 2D stress-strain extensometry between 0.03 and 0.70 N.
Results:
Twenty-six human corneas were analyzed. The mean lamella thickness was 160 ± 37 μm in corneas with Bowman layer and 155 ± 22 μm in corneas without. No statistically significant differences between flaps with and without Bowman layer were observed in the tangential elastic modulus between 5% and 20% strain (11.5 ± 2.9 kPa vs 10.8 ± 3.7 kPa, P > .278).
Conclusions:
The presence or absence of Bowman layer did not reveal a measurable difference in corneal stiffness. This may indicate that the removal of Bowman layer during photorefractive keratectomy does not represent a disadvantage to corneal biomechanics.