U-RT1 - A new model for Richter transformation

Teresa Schmid1, Julia Maier1, Melanie Martin1

  • 1Institute of Pathology, University Hospital Ulm, Ulm, Germany.

Neoplasia (New York, N.Y.)
|December 14, 2020
PubMed

Related Concept Videos

Basic Continuous Time Signals01:22

Basic Continuous Time Signals

Basic continuous-time signals include the unit step function, unit impulse function, and unit ramp function, collectively referred to as singularity functions. Singularity functions are characterized by discontinuities or discontinuous derivatives.
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
554
Routh-Hurwitz Criterion I01:15

Routh-Hurwitz Criterion I

Consider an electrical power grid, where stability is essential to prevent blackouts. The Routh-Hurwitz criterion is a valuable tool for assessing system stability under varying load conditions or faults. By analyzing the closed-loop transfer function, the Routh-Hurwitz criterion helps determine whether the system remains stable.
To apply the Routh-Hurwitz criterion, a Routh table is constructed. The table's rows are labeled with powers of the complex frequency variable s, starting from the...
416
Transformations of Functions III01:20

Transformations of Functions III

Transformations modify the graphical representation of a function without changing its fundamental form. One common transformation is reflection, which flips the graph across a designated axis. When the vertical coordinates of all points are multiplied by the negative one, the entire graph is mirrored over the horizontal axis. This transformation reverses the vertical orientation of peaks and troughs, akin to signal inversion in electrical systems, where a waveform is flipped, but the timing of...
56
Routh-Hurwitz Criterion II01:19

Routh-Hurwitz Criterion II

In the application of the Routh-Hurwitz criterion, two specific scenarios can arise that complicate stability analysis.
The first scenario occurs when a singular zero appears in the first column of the Routh table. This situation creates a division by zero issues. To resolve this, a small positive or negative number, denoted as epsilon (∈), is substituted for the zero. The stability analysis proceeds by assuming a sign for ∈. If ∈ is positive, any sign change in the first...
639
Region of Convergence01:17

Region of Convergence

The z-transform is a powerful mathematical tool used in the analysis of discrete-time signals and systems. It is a crucial tool in the analysis of discrete-time systems, but its convergence is limited to specific values of the complex variable z. This range of values, known as the Region of Convergence (ROC), is fundamental in determining the behavior and stability of a system or signal. The ROC defines the region in the complex plane where the z-transform converges, which can take various...
732
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation01:24

One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation

This lesson introduces two critical methods in pharmacokinetics, the Wagner-Nelson and Loo-Riegelman methods, used for estimating the absorption rate constant (ka) for drugs administered via non-intravenous routes. The Wagner-Nelson method relates ka to the plasma concentration derived from the slope of a semilog percent unabsorbed time plot. However, it is limited to drugs with one-compartment kinetics and can be impacted by factors like gastrointestinal motility or enzymatic degradation.
On...
930