Related Experiment Video
Updated: Nov 25, 2025

Automatic Laser-based Geometry Capture for Finite Element Analysis of Weld Beads
Published on: July 25, 2025
Automatic Calibration of a Two-Axis Rotary Table for 3D Scanning Purposes
Livio Bisogni1, Ramtin Mollaiyan1, Matteo Pettinari1
1Dipartimento di Ingegneria Civile e Industriale, Università di Pisa, Largo Lucio Lazzarino 1, 56122 Pisa, Italy.
Abstract:
Rotary tables are often used to speed up the acquisition time during the 3D scanning of complex geometries. In order to avoid manual registration of the point clouds acquired with different orientations, automatic algorithms to compensate the rotation were developed. Alternatively, a proper calibration of the rotary axis with respect to the camera system is needed. Several methods are available in the literature, but they only consider a single-axis calibration. In this paper, a method for the simultaneous calibration of both axes of the table is proposed. A checkerboard is attached to the table, and several images with different poses are acquired. An optimization algorithm is then setup to determine the orientation and the locations of the two axes. A metric to assess the calibration quality was also defined by computing the average mean reprojection error. This metric is used to investigate the optimal number and distribution of the calibration poses, demonstrating that the optimum calibration results are achieved when a wider dispersion of the calibration poses is adopted.
More Related Videos
08:27Three-Dimensional Finger Motion Tracking during Needling: A Solution for the Kinematic Analysis of Acupuncture Manipulation
Published on: October 28, 2021
08:24Sit-to-stand-and-walk from 120% Knee Height: A Novel Approach to Assess Dynamic Postural Control Independent of Lead-limb
Published on: August 30, 2016
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Adjusting a Traverse