Related Experiment Video
Updated: Nov 25, 2025

Temporal Ordering of Dynamic Expression Data from Detailed Spatial Expression Maps
Published on: February 9, 2017
Relevant out-of-time-order correlator operators: Footprints of the classical dynamics
Pablo D Bergamasco1, Gabriel G Carlo2, Alejandro M F Rivas2
1Departamento de Física, CNEA, Libertador 8250, C1429BNP Buenos Aires, Argentina.
Abstract:
The out-of-time-order correlator (OTOC) has recently become relevant in different areas where it has been linked to scrambling of quantum information and entanglement. It has also been proposed as a good indicator of quantum complexity. In this sense, the OTOC-RE theorem relates the OTOCs summed over a complete basis of operators to the second Renyi entropy. Here we have studied the OTOC-RE correspondence on physically meaningful bases like the ones constructed with the Pauli, reflection, and translation operators. The evolution is given by a paradigmatic bi-partite system consisting of two perturbed and coupled Arnold cat maps with different dynamics. We show that the sum over a small set of relevant operators is enough in order to obtain a very good approximation for the entropy and, hence, to reveal the character of the dynamics. In turn, this provides us with an alternative natural indicator of complexity, i.e., the scaling of the number of relevant operators with time. When represented in phase space, each one of these sets reveals the classical dynamical footprints with different depth according to the chosen basis.
Related Concept Videos
Basic Operations on Signals
Time Reversal mirrors a continuous-time signal about the vertical axis at t=0. This is achieved by substituting t with −t. For example, if a signal x(t) is considered, the time-reversed signal is x(−t). This operation can be graphically represented, showing the mirrored signal.
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be...
Time and frequency -Domain Interpretation of Phase-lag Control
Phase-lag controllers do not place a pole at zero, but instead influence the steady-state error by amplifying any...
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
¹H NMR: Interpreting Distorted and Overlapping Signals
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are...
Properties of DTFT I
The linearity property of DTFTs is fundamental. If two discrete-time signals are multiplied by constants a and b respectively, and then combined to...

