Related Experiment Video
Updated: Nov 25, 2025

Endotracheal Intubation via Tracheotomy and Subsequent Thoracotomy in Rats for Non-Survival Applications
Published on: March 15, 2024
Soiled airway tracheal intubation and the effectiveness of decontamination by paramedics (SATIATED): a randomised
Richard Pilbery1, M Dawn Teare2
1Yorkshire Ambulance Service NHS Trust.
Introduction:
Vomiting and regurgitation are commonly encountered in out-of-hospital cardiac arrest (OHCA), with a reported incidence of 20-30%. This is of concern since patients who have suffered an OHCA are already in extremis. If standard suctioning techniques are not sufficient to maintain a clear airway and provide ventilation, then these patients will die, irrespective of the quality of chest compressions and the timeliness of defibrillation. This study aimed to determine whether a short teaching session of the suction assisted laryngoscopy and airway decontamination (SALAD) technique improved paramedics' ability to successfully intubate a contaminated airway.
Methods:
A modified airway manikin with the oesophagus connected to a reservoir of 'vomit', and a bilge pump capable of propelling the vomit up into the oropharynx, was used to simulate a soiled airway. The intervention consisted of a brief SALAD training session with a demonstration and opportunity to practice. Participants were randomly allocated into two groups: AAB, who made two pre-training intubation attempts and one post-training attempt, and ABB, who made one pre-training and two post-training attempts, to adjust for improvement in performance due to repetition.
Results:
In this manikin study, following a brief SALAD training session, more paramedics were able to intubate a soiled airway on their first attempt, compared to those without training (90.2% vs. 53.7%, difference of 36.6%, 95% CI 24-49.1%, p < 0.001). In addition, the mean difference in time taken to perform a successful intubation between groups was statistically significant for attempts 1 and 2 (mean difference 11.71 seconds, 95% CI 1.95-21.47 seconds, p = 0.02), but not attempts 1 and 3 (mean difference -2.52 seconds, 95% CI -11.64-6.61 seconds, p = 0.58). This result is likely to be confounded by the use of tracheal suction, which only occurred in the post-training attempts and added additional time to the intubation attempts. There was no statistically significant difference in success rates on the third attempt between AAB and ABB (89.0% vs. 86.6%, difference 2.4%, 95% CI 7.6-12.4%, p = 0.63).
Conclusion:
In this study, the use of the SALAD technique significantly improved first attempt success rates when paramedics were intubating a simulated soiled airway.
Related Concept Videos
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Care II: Procedure
Step 1: Perform hand hygiene, and put on personal protective equipment: gown, gloves, mask...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...