Related Experiment Video
Updated: Nov 25, 2025

Normothermic Negative Pressure Ventilation Ex Situ Lung Perfusion: Evaluation of Lung Function and Metabolism
Published on: February 14, 2022
Lung-protective properties of expiratory flow-initiated pressure-controlled inverse ratio ventilation: A randomised
Go Hirabayashi1, Minami Saito1, Sachiko Terayama1
1Department of Anaesthesiology, Mizonokuchi Hospital Teikyo University School of Medicine, Kanagawa, Japan.
Background:
Expiratory flow-initiated pressure-controlled inverse ratio ventilation (EF-initiated PC-IRV) reduces physiological dead space. We hypothesised that EF-initiated PC-IRV would be lung protective compared with volume-controlled ventilation (VCV).
Methods:
Twenty-eight men undergoing robot-assisted laparoscopic radical prostatectomy were enrolled in this randomised controlled trial. The EF-initiated PC-IRV group (n = 14) used pressure-controlled ventilation with the volume guaranteed mode. The inspiratory to expiratory (I:E) ratio was individually adjusted by observing the expiratory flow-time wave. The VCV group (n = 14) used the volume control mode with a 1:2 I:E ratio. The Mann-Whitney U test was used to compare differences in the serum cytokine levels.
Results:
There were no significant differences in serum IL-6 between the EF-initiated PC-IRV (median 34 pg ml-1 (IQR 20.5 to 63.5)) and VCV (31 pg ml-1 (24.5 to 59)) groups (P = 0.84). The physiological dead space rate (physiological dead space/expired tidal volume) was significantly reduced in the EF-initiated PC-IRV group as compared with that in the VCV group (0.31 ± 0.06 vs 0.4 ± 0.07; P<0.001). The physiological dead space rate was negatively correlated with the forced vital capacity (% predicted) in the VCV group (r = -0.85, P<0.001), but not in the EF-initiated PC-IRV group (r = 0.15, P = 0.62). Two patients in the VCV group had permissive hypercapnia with low forced vital capacity (% predicted).
Conclusions:
There were no differences in the lung-protective properties between the two ventilatory strategies. However, EF-initiated PC-IRV reduced physiological dead space rate; thus, it may be useful for reducing the ventilatory volume that is necessary to maintain normocapnia in patients with low forced vital capacity (% predicted) during robot-assisted laparoscopic radical prostatectomy.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs...
Mechanical Ventilation I: Indication and Settings