Atrial conduction explains the occurrence of the P-wave dispersion phenomenon, but weakly
Raimundo Carmona Puerta1, Elibet Chávez González1, Magda Alina Rabassa López-Calleja2
1Department of Electrophysiology and Arrhythmology Cardiovascular Hospital "Ernesto Guevara" Santa Clara City Cuba.
Background:
P-wave dispersion (PWD) is believed to be caused by inhomogeneous atrial conduction. This statement, however, is based on limited little solid evidence. The aim of this study was to determine the relationship between atrial conduction and PWD by means of invasive electrophysiological studies.
Methods:
Cross-sectional study in 153 patients with accessory pathways and atrioventricular node reentry tachycardia (AVNRT) undergoing an electrophysiological study. Different atrial conduction times were measured and correlated with PWD.
Results:
Only the interatrial (P-DCS) and left intra-atrial conduction times (ΔDCS-PCS) showed a significant correlation with PWD, but this correlation was weak. Multivariate linear regression analysis determined that both P-DCS (β = 0.242; P = .008) and ΔDCS-PCS (β = 0.295; P < .001) are independent predictors of PWD. Performing the multivariate analysis for arrhythmic substrates, it is observed that only ΔDCS-PCS continued to be an independent predictor of PWD. Analysis of the receiver operating characteristic curves showed that regardless of the types of arrhythmic substrates, PWD discriminates significantly, but moderately, to patients with P-DCS and ΔDCS-PCS ≥75 percentile.
Conclusions:
Interatrial and intraleft atrial conduction times were directly and significantly correlated with PWD, but only weakly, and were independent predictors of PWD. In general, PWD correctly discriminates patients with high values in interatrial and intraleft atrial conduction times, but moderately. This is maintained in cases with accessory pathways; however, in patients with AVNRT it only does so for intraleft atrial conduction times. Interatrial and intraleft atrial conduction times weakly explains PWD.
Related Concept Videos
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Conduction System of the Heart
This system relies on the unique properties of nodal and Purkinje cells:...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Mechanism of Cardiac Arrhythmias
Electrophysiology of Normal Cardiac Rhythm
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials