Related Experiment Video
Updated: Nov 25, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Early use of remote dielectric sensing after hospitalization to reduce heart failure readmissions
Anuradha Lala1,2, Maya H Barghash1, Gennaro Giustino1,2
1Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, One Gustave Levy Place, PO Box 1030, New York, NY, 10129, USA.
Aims:
Readmission after hospitalization for acute decompensated heart failure (HF) remains a major public health problem. Use of remote dielectric sensing (ReDS) to measure lung water volume allows for an objective assessment of volume status and may guide medical optimization for HF. We hypothesized that the use of ReDS would lower 30 day readmission in patients referred to rapid follow-up (RFU) clinic after HF discharge.
Methods And Results:
We conducted a retrospective analysis of the use of ReDS for patients scheduled for RFU within 10 days post-discharge for HF at Mount Sinai Hospital between 1 July 2017 and 31 July 2018. Diuretics were adjusted using a pre-specified algorithm. The association between use of ReDS and 30 day readmission was evaluated. A total of 220 patients were included. Mean age was 62.9 ± 14.7 years, and 36.4% were female. ReDS was performed in 80 (36.4%) and led to medication adjustment in 52 (65%). Use of ReDS was associated with a lower rate of 30 day cardiovascular readmission [2.6% vs. 11.8%, hazard ratio (HR): 0.21; 95% confidence interval (CI): 0.05-0.89; P = 0.04] and a trend towards lower all-cause readmission (6.5% vs. 14.1%, HR: 0.43; 95% CI: 0.16-1.15; P = 0.09) as compared with patients without a ReDS assessment.
Conclusions:
ReDS-guided HF therapy during RFU after HF hospitalization may be associated with lower risk of 30 day readmission.
More Related Videos
05:16Cutoff Value of Phase Angle by Bioelectrical Impedance Analysis at Admission as a Prognostic Factor in Patients with Acute Heart Failure
Published on: June 10, 2025
16:40A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Holter Monitor: 24-Hour Monitoring
Heart Failure VI: Adjunct Therapies
Cardiomyopathy V: Interprofessional Care
Cardiomyopathy II: Dilated Cardiomyopathy
Rheumatic Heart Disease IV: Nursing Management