Accuracy of a spontaneous breathing trial for extubation of neonates
M Fiatt1, A C Bosio1, D Neves1
1Hospital Criança Conceição, Neonatal Intensive Care Unit, Porto Alegre, Brazil.
Background:
Prevalence of extubation failure in neonates may be up to 80%, but evidence to determine if a neonate is ready for extubation remains unclear. We aim to evaluate a spontaneous breathing trial accuracy with minimum pressure support to predict success in neonates' extubation and identify variables related to failures.
Methods:
This is a diagnostic accuracy study based on a cohort study in an intensive care unit with all eligible newborn infants subjected to invasive mechanical ventilation for at least 24 hours submitted to the trial for 10 minutes before extubations. The outcome was failures of extubations, considered if reintubation was needed until 72 hours.
Results:
The incidence of failure was 14.7%among 170 extubations. There were 145 successful extubations; of these, 140 also passed the trial with a sensitivity of 96.5%(95%CI: 92.1-98.9). Of the 25 extubations that eventually failed, 16 failed the test with a specificity of 64.0%(95%CI: 42.5-82.0). The negative predictive value was 76.2%, and the positive predictive value was 94%. In stratifying by weight, the accuracy was >98.7%for neonates weighting >2500 g, but 72.5%for those weighing <1250 g. Extubation failures occurred more frequently in smaller (p = 0.01), preterm infants (p = 0.17), with longer ventilation time (p = 0.05), and having a hemodynamically significant persistent arterial duct (p = 0.01), compared with infants whose extubation was successful.
Conclusion:
The spontaneous breathing trial with minimum pressure support ventilation seems to predict extubation success with great accuracy in full-term and larger neonates.
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Respiratory Volumes and Capacities I
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...