Quantification of Lambda (Λ) in multi-elemental compound-specific isotope analysis
Related Experiment Video
Updated: Nov 25, 2025

Author Spotlight: Technologies and Challenges in Elemental Analysis of Food Samples
Published on: December 22, 2023
Patrick Höhener1, Gwenaël Imfeld2
1Aix Marseille University - CNRS, UMR 7376, Laboratory of Environmental Chemistry, Marseille, France.
Abstract:
In multi-elemental compound-specific isotope analysis the lambda (Λ) value expresses the isotope shift of one element versus the isotope shift of a second element. In dual-isotope plots, the slope of the regression lines typical reveals the footprint of the underlying isotope effects allowing to distinguish degradation pathways of an organic contaminant molecule in the environment. While different conventions and fitting procedures are used in the literature to determine Λ, it remains unclear how they affect the magnitude of Λ. Here we generate synthetic data for benzene δ2H and δ13C with two enrichment factors εH and εC using the Rayleigh equation to examine how different conventions and linear fitting procedures yield distinct Λ. Fitting an error-free data set in a graph plotting the δ2H versus δ13C overestimates Λ by 0.225%⋅εH/εC, meaning that if εH/εCis larger than 22, Λ is overestimated by more than 5%. The correct fitting of Λ requires a natural logarithmic transformation of δ2H versus δ13C data. Using this transformation, the ordinary linear regression (OLR), the reduced major-axis (RMA) and the York methods find the correct Λ, even for large εH/εC. Fitting a dataset with synthetic data with typical random errors let to the same conclusion and positioned the suitability of each regression method. We conclude that fitting of non-transformed δ values should be discontinued. The validity of most previous Λ values is not compromised, although previously obtained Λ values for large εH/εC could be corrected using our error estimation to improve comparison.
More Related Videos
Related Concept Videos
Mass Spectrometry: Isotope Effect
Atomic Emission Spectroscopy: Lab
Mass Spectrum: Interpretation
To...
Atomic Emission Spectroscopy: Overview
High-Resolution Mass Spectrometry (HRMS)
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences