Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Upsampling01:22

Upsampling

470
Managing signal sampling rates is essential in digital signal processing to maintain signal integrity. A decimated signal, characterized by a reduced frequency range due to its lower sampling rate, can be upsampled by inserting zeros between each sample. This upsampling process expands the original spectrum and introduces repeated spectral replicas at intervals dictated by the new Nyquist frequency. To refine this zero-inserted sequence, it is passed through a lowpass filter with a cutoff...
470
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

8.5K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
8.5K
Aliasing01:18

Aliasing

400
Accurate signal sampling and reconstruction are crucial in various signal-processing applications. A time-domain signal's spectrum can be revealed using its Fourier transform. When this signal is sampled at a specific frequency, it results in multiple scaled replicas of the original spectrum in the frequency domain. The spacing of these replicas is determined by the sampling frequency.
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
400
Computed Tomography01:10

Computed Tomography

7.6K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
7.6K
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

561
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
561

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

PhotIQA: A photoacoustic image data set with image quality ratings.

Scientific data·2026
Same author

Seven tesla MRI reveals amygdala and hippocampal subfield atrophy in dementia with Lewy bodies.

Alzheimer's research & therapy·2026
Same author

Real-time CBCT reconstructions using Krylov solvers in repeated scanning procedures.

Physics in medicine and biology·2026
Same author

Functional hypothalamic MR spectroscopy at 7 Tesla: Metabolic shifts in response to food image stimuli and associations with hypothalamic volume and body mass index.

NeuroImage·2026
Same author

From Coarse to Continuous: Progressive Refinement Implicit Neural Representation for Motion-Robust Anisotropic MRI Reconstruction.

IEEE transactions on image processing : a publication of the IEEE Signal Processing Society·2026
Same author

Hierarchical Multiscale Structure-Function Coupling for Brain Connectome Integration.

ArXiv·2026

Related Experiment Video

Updated: Nov 25, 2025

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
05:07

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods

Published on: September 6, 2024

583

Compressed sensing plus motion (CS + M): A new perspective for improving undersampled MR image reconstruction.

Angelica I Aviles-Rivero1, Noémie Debroux2, Guy Williams3

  • 1Department of Pure Mathematics and Mathematical Statistics, University of Cambridge, UK.

Medical Image Analysis
|December 20, 2020
PubMed
Summary

This study introduces a new dynamic MRI reconstruction method, Compressed Sensing Plus Motion (CS+M), to improve image quality from undersampled data. The CS+M model effectively reduces blurring and preserves details in medical imaging.

Keywords:
Compressed sensingDynamic MRIImage reconstructionMotion estimationVariational methods

More Related Videos

Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases
09:55

Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases

Published on: January 5, 2024

1.6K
Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.7K

Related Experiment Videos

Last Updated: Nov 25, 2025

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
05:07

Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods

Published on: September 6, 2024

583
Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases
09:55

Author Spotlight: Using Hyperpolarized Xenon-129 MRI to Study Lung Diseases

Published on: January 5, 2024

1.6K
Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform
06:25

Time Multiplexing Super Resolving Technique for Imaging from a Moving Platform

Published on: February 12, 2014

8.7K

Area of Science:

  • Medical Imaging
  • Image Reconstruction
  • Computational Imaging

Background:

  • Undersampled Magnetic Resonance Imaging (MRI) data acquisition presents significant challenges for high-quality image reconstruction.
  • Dynamic MRI scans are particularly susceptible to motion-induced blurring and loss of fine details, degrading diagnostic accuracy.

Purpose of the Study:

  • To develop an advanced framework for dynamic MRI reconstruction that simultaneously addresses image quality and motion artifacts.
  • To introduce a novel multi-task optimization model, Compressed Sensing Plus Motion (CS+M), for improved undersampled MRI data reconstruction.

Main Methods:

  • Propose a unified optimization problem to concurrently reconstruct MRI images and estimate physical motion.
  • Decompose the complex optimization problem into two computationally manageable sub-problems for efficient solving.
  • Validate the CS+M framework across diverse clinical applications, including cardiac cine, cardiac perfusion, and brain perfusion imaging.

Main Results:

  • Demonstrate significant reduction in blurring artifacts in reconstructed dynamic MRI images.
  • Showcase the preservation of target shape and fine details, crucial for accurate medical diagnosis.
  • Achieve superior reconstruction quality compared to state-of-the-art techniques, especially at high undersampling rates.

Conclusions:

  • The proposed CS+M framework offers a robust and efficient solution for high-quality dynamic MRI reconstruction from undersampled data.
  • The model's ability to handle motion artifacts and undersampling enhances its clinical applicability and generalizability.
  • This approach represents a significant advancement in medical imaging, improving diagnostic capabilities through enhanced image fidelity.