Comminuted patellar fractures: The role of biplanar fixed angle plate constructs
Mauricio Kfuri1, Igor Escalante2, Clemens Schopper2,3
1Department of Orthopaedic Surgery, University of Missouri, Columbia, MO, United States.
Background:
Comminuted patellar fractures represent a challenging clinical problem. Treatment aims to restore the integrity of the extensor mechanism and the congruity of patellofemoral joint. Controversy exists regarding the ideal fixation method. Metallic constructs aiming to convert pulling forces on the anterior aspect of the patella into compression forces across the fracture site are the standard of care. More recently, low profile plates have been described in the management of comminuted patellar fractures. The aims of this study were to (1) develop a novel unstable patellar fracture model and (2) to compare biomechanically three different constructs for fixation comminuted patellar fractures. We hypothesized that an orthogonal biplanar disposition of the screws within an anteriorly placed locking plate provides the best biomechanical properties in the management of comminuted fractures.
Methods:
Six-part complex AO 34-C3 patella fractures were simulated in 18 human cadaveric knees by means of osteotomies including comminution around the distal patellar pole. The specimens were randomly assigned to 3 fixation techniques (n = 6) for either anterior plating, antero-lateral plating, or tension band wiring (TBW). Biomechanical testing was performed over 5000 cycles in active extension and passive flexion, followed by ultimate destructive quasi-static testing. Interfragmentary movements were captured by means of optical motion tracking.
Results:
Displacement between the proximal and distal medial patella fragments was lower after anterior plating compared to both antero-lateral plating (P = 0.084) and TBW (P < 0.001). Moreover, displacement between the proximal and distal lateral fragments was significantly lower after anterior plating compared to both other techniques (P ≤ 0.032). In addition, it was significantly lower for antero-lateral plating versus TBW (P < 0.001). Rotation around the medio-lateral axis between the proximal and distal medial fragments was significantly lower after anterior plating compared to TBW (P = 0.017).
Conclusions:
Anterior mesh plating with biplanar placement of locking screws provides superior stability for fixation of comminuted patellar fractures when compared to both antero-lateral mesh plating and TBW. The latter is associated with considerably inferior performance.
More Related Videos
07:35Creating Rigidly Stabilized Fractures for Assessing Intramembranous Ossification, Distraction Osteogenesis, or Healing of Critical Sized Defects
Published on: April 11, 2012
05:34A Mini-Invasive Internal Fixation Technique for Studying Immobilization-Induced Knee Flexion Contracture in Rats
Published on: May 20, 2019
Related Concept Videos
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bones of the Lower Limb: Femur and Patella