A rare case of peri-implant distal radius fracture
Leonardo Stramazzo1, Alessio Cioffi1, Giuseppe Rovere2
1Department of Orthopaedic Surgery (DICHIRONS), University of Palermo, Palermo, Italy.
Abstract:
A peri-implant fracture near the volar plate of distal radius represent a very rare injury. The main factor of this lesion is high energy trauma on the wrist. We report a case of a 61-year-old woman with a peri-implant fracture located just proximally to the plate and a fracture of the ulnar head that occurred after a simple fall. The patient was surgically treated by plate and screws removal. The fracture was fixed using a longer volar plate for the radial fracture and a plate for the head ulnar fracture. Different factors such as osteoporosis, BMI and screw position could influence the fracture pattern. However, considering growing use of plates for distal radius fracture fixation, the frequency of these kind of fracture will probably increase.
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...