Related Experiment Video
Updated: Nov 24, 2025

Collection of Alfalfa Root Exudates to Study the Impact of Di2-ethylhexyl Phthalate on Metabolite Production
Published on: June 2, 2023
Associations of dermal diethyl phthalate level with changes in lung function test value mediated by absolute
Chih-Wen Wang1, Da-Wei Wu2, Szu-Chia Chen3
1Division of Hepatobiliary, Department of Internal Medicine, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan; Department of Internal Medicine, Kaohsiung Municipal Siaogang Hospital, Kaohsiung Medical University, Kaohsiung, Taiwan; Center for Cancer Research, Kaohsiung Medical University, Kaohsiung, Taiwan.
Abstract:
Phthalate concentrations in indoor and outdoor dust are associated with respiratory disease. Both immunoglobulin E (IgE) and eosinophil count are associated with airway inflammation from exposure to environmental allergens. Dermal phthalate level can be used as a matrix for assessing personal exposure through direct absorption from the air, particle deposition, or contact with contaminated products. However, the association between dermal phthalate level and changes in lung function test values, as mediated by immunological response, remains unclear. In total, 237 adults in southern Taiwan were recruited. Spirometry measurements (in L) of forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) were taken on visits 1 (2016-2018) and 2 (2019). Dermal phthalate level, absolute eosinophil count, and IgE level were recorded on visit 1. Mean changes in FVC and FEV1 decrease pear year, as determined through pairwise comparisons, were significant (diffFVCper year: -0.46, 95% CI: -0.51, -0.41; p < 0.001; diffFEV1per year: -0.37, 95% confidence interval [CI]: -0.41, -0.34; p < 0.001). For FEV1 decrease, log-unit increases in dermal diethyl phthalate (DEP) were positively associated with diffFEV1per year (β = 0.096; 95% CI: 0.042, 0.150; p = 0.001) and negatively associated with absolute eosinophil count (β= -0.201; 95% CI: -0.380, -0.023; p= 0.027). Log-unit increases in absolute eosinophil count were negatively associated with diffFEV1per year (β= -0.109; 95% CI: -0.150, -0.068; p < 0.001). Absolute eosinophil count mediated 19.70% of the association between dermal DEP level and diffFEV1per year. For FVC decrease, log-unit increases in dermal DEP were positively associated with diffFVCper year (β = 0.095; 95% CI: 0.035, 0.155; p = 0.002) and negatively associated with absolute eosinophil count (β = -0.243; 95% CI: -0.427, -0.060; p = 0.010). Log-unit increases in absolute eosinophil count were negatively associated with diffFVCper year (β= -0.122; 95% CI: -0.168, -0.076; p < 0.001). Absolute eosinophil count mediated 29.98% of the association between dermal DEP level and diffFVCper year. The results suggest that dermal DEP level is positively associated with changes in lung function test values and is mediated by absolute eosinophil count.
More Related Videos
08:44Identification and Characterization of Immunogenic RNA Species in HDM Allergens that Modulate Eosinophilic Lung Inflammation
Published on: May 30, 2020
06:34A Component-resolved Diagnostic Approach for a Study on Grass Pollen Allergens in Chinese Southerners with Allergic Rhinitis and/or Asthma
Published on: June 4, 2017