Background And Objectives:
Despite expander-based breast reconstruction being used as a reliable reconstruction method, implant removal due to wound dehiscence and infection still occurs in 0.5% to 15% of cases. This study aimed to compare the outcomes of the new inframammary fold (IMF) incision approach with previous incision in second-stage operation of expander-based 2-stage breast reconstruction.
Methods:
Patients who underwent expander-based 2-stage breast reconstruction between February 2014 and May 2019 were included. After expander inflation, patients undergoing second-stage reconstruction were divided into the previous incision and IMF incision groups and their outcomes were compared. Propensity score matching analysis was performed to compare postoperative 1-year results.
Results:
The previous incision and IMF incision groups comprised 79 and 31 patients, respectively. There were no intergroup differences in general demographics or intraoperative data, except for total inflation volume (426.87 ± 102.63 mL in the previous incision group and 375.48 ± 94.10 mL in the IMF incision group, P = 0.017). Wound dehiscence occurred in 12 and 0 cases in the previous and IMF incision groups, respectively (P = 0.018). Implant removal was performed due to dehiscence in 9 cases (8.18%) and 0 cases (0%) in the previous and IMF incision groups, respectively (P = 0.049). In 1-to-1 propensity score matching analysis, the IMF incision group showed better results at 1-year follow-up (odds ratio: 0, 95% confidence interval: 0-1.09; P = 0.063).
Conclusions:
The IMF approach is a safe method for replacing the expander with an implant, with lower incidence of wound dehiscence and implant explantation.