Related Experiment Video
Updated: Nov 24, 2025

Four-Dimensional CT Analysis Using Sequential 3D-3D Registration
Published on: November 23, 2019
[Diagnostic value of a 3D-SPACE-sequence with compressed sensing technology for the knee joint]
Corina Pfeifer1, Ulrike Attenberger2, Stefan O Schoenberg3
1Radiologisches Zentrum für Diagnostik und Therapie München, Oberföhringer Straße 2, 81679, München, Deutschland.
Backround:
SPACE (3D fast spin echo acquisition) sequences require long scan times for three-dimensional assessment of acute injury of the knee joint and are flawed due to geometric blurring. Their implementation into routine diagnostic imaging was not feasible until recently.
Objectives:
By comparing conventional MRI (magnetic resonance imaging) sequences to 3D (three-dimensional) sequences, it was investigated whether the compressed sensing (CS) technique is inferior to the established 2D sequences with shorter examination times.
Materials And Methods:
A total of 109 patients (age range 18-50 years) with knee injury were examined by MRI between April 2017 and May 2018. The inter- and intraobserver concordance of two blinded readers were assessed. Consensus was achieved in case of discrepancies. Descriptive analyses of absolute and relative frequency and distribution were tested by Fisher's exact test concerning differences between CS-SPACE and standard proton density fat suppressed imaging.
Results:
Interoberserver concordance (IC) of conventional sequences before/after consensus amounted to 58.8/68.1% (medial meniscus, MM), 68.8/88.7% (lateral meniscus, LM) 88.9/97.2% (anterior cruciate ligament, ACL), 99/100% (posterior cruciate ligament, PCL), 88.9/97.2% (collateral ligament, CL) and chondral injury (CI) 1-2: 64.2%, CI-3: 77% and CI-4: 76%. The IC of CS-SPACE amounted before/after consensus of MM to 50.4/77%, LM 68.8/88%, ACL 89.9/94.5%, PCL 97.2/99.0%, CL 92.6/96.3%. IC of CI was evaluated without consensus and amounted to 65.1% (CI 1-2), 66% (CI 3) and 81.6% (CI 4).
Conclusions:
Injuries of ACL, PCL and CL have excellent IC between 3D and 2D sequences. Excellent IC could be found in CI grade 3 and 4 when using 2D sequences and CI grade 4 utilizing CS-SPACE. Our results indicate that CS-SPACE is useful in diagnosing acute knee injuries.
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Knee Joint
A total of seven ligaments support the knee joint. The patellar ligament, which is also attached to the quadriceps femoris...

