Masking Between Reserved Alarm Sounds of the IEC 60601-1-8 International Medical Alarm Standard: A Systematic, Formal

Matthew L Bolton1, Judy R Edworthy2, Andrew D Boyd3

  • 112292 University at Buffalo, The State University of New York, USA.

Human Factors
|December 22, 2020
PubMed
Abstract

Related Concept Videos

Operational Amplifiers01:17

Operational Amplifiers

The operational amplifier, often referred to as an op-amp, is a multifaceted building block of a circuit. This electronic component functions like a voltage-controlled voltage source and can also be used to create a voltage- or current-controlled current source. The design of an operational amplifier enables it to execute mathematical operations when external components like resistors and capacitors are linked to its terminals. An op-amp has the capacity to sum signals, amplify a signal,...
1.7K
Instrumentation Amplifier01:25

Instrumentation Amplifier

An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
849
Masking and Demasking Agents01:19

Masking and Demasking Agents

EDTA titrations may necessitate masking and demasking agents to temporarily protect a particular metal ion in a mixture from the EDTA reaction. These agents facilitate the sequential analysis of the metal ions by forming stable complexes with some—but not all—metal ions during certain steps.
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
3.1K
Korotkoff Sounds01:12

Korotkoff Sounds

Korotkoff sounds are the specific sounds heard while measuring blood pressure using a sphygmomanometer, typically with a stethoscope or a Doppler device. They are named after Russian physician Nikolai Korotkov, who first described them in 1905. These sounds correspond to turbulent blood flow in the artery as the blood pressure cuff is gradually released after inflation.
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
6.0K