Related Experiment Video
Updated: Nov 24, 2025

Tuning a Parallel Segmented Flow Column and Enabling Multiplexed Detection
Published on: December 15, 2015
Three approaches to improving performance of liquid chromatography using contour maps with pressure, time, and number
Masahito Ito1, Katsutoshi Shimizu2, Kiyoharu Nakatani3
1Division of Chemistry, Faculty of Pure and Applied Sciences, University of Tsukuba, 1-1-1 Tennoudai, Tsukuba, Ibaraki 305-8571, Japan; Hitachi High-Tech Science Corporation, 1-17-1 Toranomon, Minato-ku, Tokyo 105-6411, Japan.
Abstract:
Attempts to improve HPLC performance often focus on increasing the speed or separation performance. In this article, both the flow rate and column length are optimized as separation conditions, while observing the number of theoretical plates and hold-up time with isocratic elutions. In addition, the upper pressure limit must be simultaneously considered as the boundary condition. Approaches based on the optimal velocity (Opt.) are often adopted; but the kinetic performance limit (KPL) in Desmet's method can also be utilized for three-dimensional graphing with axes of pressure, time, and number of theoretical plates. Here, two approaches involving pressure increase are introduced, beginning with the condition of optimal linear velocity: one aimed at greater speed and the other at higher resolution. Coefficients of pressure-application are derived to measure the effectiveness of the intermediate conditions between the Opt. and KPL methods. In the third approach, the hold-up time is extended while maintaining a fixed pressure. Coefficients of time-extension are also derived, to determine the effectiveness to improve the separation performance.
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
High-Performance Liquid Chromatography: Instrumentation
Column Efficiency: Plate Theory
A higher number of theoretical plates signifies better column efficiency and improved separation capabilities. Plate height affects bandwidth and separation quality; it is inversely...
High-Performance Liquid Chromatography: Elution Process
Chromatographic Methods: Terminology