Related Experiment Video
Updated: Nov 24, 2025

Whole Cell Patch Clamp for Investigating the Mechanisms of Infrared Neural Stimulation
Published on: July 31, 2013
Infrared neural stimulation at different wavelengths and pulse shapes
Yingyue Xu1, Mario Magnuson2, Aditi Agarwal2
1Department of Otolaryngology, Northwestern University Feinberg School of Medicine, 303 E. Chicago Ave, Searle 12-561, Chicago, IL, 60611, USA; Department of Communication Sciences and Disorders, Northwestern University, Frances Searle Building, 2240 Campus Drive, Evanston, IL, 60208, USA.
Abstract:
Neural stimulation with infrared radiation has been explored for brain tissue, peripheral nerves, and cranial nerves including the auditory nerve. Initial experiments were conducted at wavelengths between λ = 1850 and λ = 2140 nm and the radiant energy was delivered with square pulses. Water absorption of the infrared radiation at λ = 1860 nm is similar to absorption at wavelengths between λ = 1310 and λ = 1600 nm, which are in the radiation wavelength range used for the communication industry. Technology for those wavelengths has already been developed and miniaturized and is readily available. The possibility of the infrared light to evoke compound action potentials (CAP) in the cochlea at λ = 1,375, λ = 1,460, and λ = 1550 nm was explored and compared to that of λ = 1860 nm in guinea pigs. Furthermore, rise and fall times of the 100 μs long pulses were changed and four basic pulse shapes (square, triangular, ramp-up, and ramp-down) were explored in their ability to evoke a CAP. In animals with pure tone threshold averages (PTAs) above 70 dB SPL, the results show that the favorable wavelength is λ = 1460 nm to reach threshold for stimulation and λ = 1375 nm or λ = 1460 nm for obtaining maximum amplitude. The most favorable pulse shape is either ramp-up or triangular.