A Comparison of Different Calibration Techniques for Hydrophones Used in Medical Ultrasonic Field Measurement
Abstract:
The acoustic output characterization of medical ultrasonic equipment requires regular calibration of the hydrophones used to ensure the reliability of measurements. Such hydrophone calibration is offered as a service by several institutions. Various calibration techniques using a variety of ultrasonic excitation pressure waveforms comprising different pressure amplitude ranges and frequency compositions as well as different reference measurement systems have been proposed and applied over the past decades. Currently, four different setups for hydrophone calibration are available at the Physikalisch-Technische Bundesanstalt (PTB). This internal comparison study addresses the consistency of all four methods, including direct primary calibration and substitution calibration using reference hydrophones. The methods apply single-frequency tonebursts and swept tonebursts in the kPa amplitude range of quasi-linear acoustics as well as impulse excitation including nonlinear propagation. In recent years, a new primary calibration setup using a high-frequency vibrometer has been implemented at PTB, enabling the characterization of hydrophone frequency responses in modulus and phase and extending the upper frequency limit to up to 100 MHz. For the comparison in the frequency range from 0.5 MHz to 60 MHz, two passive membrane hydrophones with well-known characteristics gained from many years of measurements were used. Another membrane hydrophone with a nominal diameter of 0.2 mm and an integrated preamplifier was applied to address the frequency range up to 100 MHz. The results obtained with the different setups showed good agreement with average root-mean-square (rms) deviations of 3% (primary calibrations, 1-60 MHz) and 4% (1-100 MHz). The consistency of the implementations was thus verified in this comparison.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...