Related Experiment Video
Updated: Nov 24, 2025

Development and Functionalization of Electrolyte-Gated Graphene Field-Effect Transistor for Biomarker Detection
Published on: February 1, 2022
An efficient and simple method using a graphite oxide electrochemical sensor for the determination of glyphosate in
Jaqueline S Santos1, Montcharles S Pontes2, Etenaldo F Santiago2
1Department of Plant Resources, Natural Resources Program (PGRN), Mato Grosso do Sul State University (UEMS), P.O. Box 351, Dourados, MS 7984-970, Brazil; Department of Analytical Chemistry, Natural Resources Program (PGRN), Mato Grosso do Sul State University (UEMS), P.O. Box 351, Dourados, MS 7984-970, Brazil.
Abstract:
Excessive and indiscriminate use of the herbicide glyphosate (GLY) leaves the environment susceptible to its contamination. This work describes the development of a simple, inexpensive, and efficient electroanalytical method using graphite oxide paste electrode (GrO-PE) for the direct determination of GLY traces in groundwater samples, soybean extracts, and lettuce extracts. Under optimal experimental conditions, the developed sensor exhibited a linear response of the peak current intensity vs. the concentration, in the range of 1.8 × 10-5 to 1.2 × 10-3 mol L-1 for GLY. The limits of detection and quantification are 1.7 × 10-8 mol L-1 and 5.6 × 10-8 mol L-1, respectively. The methodology developed here demonstrated a strong analytical performance, with high reproducibility, repeatability, and precision. Moreover, it successfully avoided interference from other substances, showing high selectivity. The GrO-PE sensor was effectively applied to determine GLY traces in real samples with recovery rates ranging from 98% to 102%. Results showed that the GrO-PE is effective and useful for GLY detection, with the advantage of not involving laborious modifications and complicated handling, making it a promising tool for environmental analysis.
More Related Videos
11:18Manufacturing of a Nafion-coated, Reduced Graphene Oxide/Polyaniline Chemiresistive Sensor to Monitor pH in Real-time During Microbial Fermentation
Published on: January 7, 2019
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Related Concept Videos
Electrogravimetric Analysis: Overview
To test the completeness of the...
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...