Related Experiment Video
Updated: Nov 23, 2025

Standardized Histomorphometric Evaluation of Osteoarthritis in a Surgical Mouse Model
Published on: May 6, 2020
Scoring Osteoarthritis Reliably in Large Joints and the Spine Using Whole-Body CT: OsteoArthritis Computed
Willem Paul Gielis1,2, Harrie Weinans1, Frank J Nap3
1Department of Orthopaedics, University Medical Center Utrecht, Utrecht University, 3584 CX Utrecht, The Netherlands.
Abstract:
A standardized method to assess structural osteoarthritis (OA) burden thorough the body lacks from literature. Such a method can be valuable in developing personalized treatments for OA. We developed a reliable scoring system to evaluate OA in large joints and the spine-the OsteoArthritis Computed Tomography (OACT) score, using a convenience sample of 197 whole-body low-dose non-contrast CTs. An atlas, containing example images as reference points for training and scoring, are presented. Each joint was graded between 0-3. The total OA burden was calculated by summing scores of individual joints. Intra- and inter-observer reliability was tested 25 randomly selected scans (N = 600 joints). Intra-observer reliability and inter-observer reliability between three observers was assessed using intraclass correlation coefficient (ICC) and square-weighted kappa statistics. The square-weighted kappa for intra-observer reliability for OACT-score at joint-level ranged from 0.79 to 0.95; the ICC for the total OA grade was 0.97 (95%-CI, 0.94 to 0.99). Square-weighted kappa for interobserver reliability ranged from 0.48 to 0.95; the ICC for the total OA grade was 0.95 (95%-CI, 0.90 to 0.98). The OACT score, a new reproducible CT-based grading system reflecting OA burden in large joints and the spine, has a satisfactory reproducibility. The atlas can be used for research purposes, training, educational purposes and systemic grading of OA on CT-scans.
More Related Videos
08:52Software-Assisted Quantitative Measurement of Osteoarthritic Subchondral Bone Thickness
Published on: March 18, 2022
06:28Anterior Cruciate Ligament Transection and Synovial Fluid Lavage in a Rodent Model to Study Joint Inflammation and Posttraumatic Osteoarthritis
Published on: September 2, 2025
Related Concept Videos
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography