Related Experiment Video
Updated: Nov 23, 2025

Atomic Layer Deposition of Vanadium Dioxide and a Temperature-dependent Optical Model
Published on: May 23, 2018
A novel direct-immersion single-drop microextraction combined with digital colorimetry applied to the determination
Leane Santos Nunes1, Maria Graças Andrade Korn2, Valfredo Azevedo Lemos1
1Universidade Federal da Bahia, Programa de Pós-Graduação Em Química, Campus Universitário de Ondina, Salvador, Bahia, 40170-280, Brazil; Universidade Estadual Do Sudoeste da Bahia, Laboratório de Química Analítica (LQA), Campus de Jequié, Jequié, Bahia, 45206-510, Brazil.
Abstract:
In this study, a method based on direct-immersion single-drop microextraction was developed for the determination of vanadium in water. The detection system uses digital images obtained directly from the solvent drop after the sorption of V(V). The extraction solvent used was the ionic liquid 1-hexyl-3-methylimidazolium hexafluorophosphate ([C6MIM][PF6]). The images were obtained directly from the solvent drop, with the aid of a camera. The digital images were stored, and the RGB (red, green, and blue) data were obtained. The data collected by the red channel were used to construct the analytical curve since it showed higher sensitivity compared with green and blue channels. Under optimized conditions, the method presented an enrichment factor of 50 and a limit of detection of 0.6 μg L-1 for 3.5 mL sample volume. The limit of quantification and the relative standard deviation (50.0 μg L-1) obtained were 1.8 μg L-1 and 4.8%, respectively. Certified reference material (Plankton) was used to assess the accuracy of the method. The simple, fast, efficient, and low-cost procedure was successfully applied to the determination of V(V) in water samples. The proposed method is also following the principles of green chemistry since it uses minimal volumes of samples, reagents, and solvents and yields a small amount of waste.
More Related Videos
10:31Detection and Recovery of Palladium, Gold and Cobalt Metals from the Urban Mine Using Novel Sensors/Adsorbents Designated with Nanoscale Wagon-wheel-shaped Pores
Published on: December 6, 2015
11:43Dissolved Solute Sampling Across an Oxic-Anoxic Soil-Water Interface Using Microdialysis Profilers
Published on: March 24, 2023
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetric Techniques: Linear-Scan (E vs Time)
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Voltammetric Techniques: Pulse Voltammetry
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
EDTA: Indirect and Alkalimetric Titration