Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

558
Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next...
558
NMR Spectrometers: Resolution and Error Correction01:14

NMR Spectrometers: Resolution and Error Correction

926
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
926
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)01:20

¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)

1.4K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.4K
Difference from Background: Limit of Detection01:05

Difference from Background: Limit of Detection

7.8K
The limit of detection (LOD) is the smallest amount of analyte that can be distinguished from the background noise. The LOD value corresponds to the concentration at which the analyte signal is three times larger than the standard deviation of the blank signal. Below this value, the analyte signal cannot be differentiated from the background noise. It is calculated by dividing the calibration slope by 3 times the standard deviation of the blank signals.
The LOD indicates the presence or absence...
7.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Single-view neural illumination estimation and editing for dynamic light field display.

Light, science & applications·2026
Same author

Multi-view multi-focal 3D display using light source array and focus tunable optics.

Optics express·2025
Same author

Quality enhancement of computer-generated hologram without contents-dependent optimization by considering aberrations in the optical system.

Optics express·2025
Same author

Improved color uniformity in monochrome holographic waveguide based near eye displays.

Optics express·2025
Same author

Field of view and angular-resolution enhancement in microlens array type virtual reality near-eye display using polarization grating.

Optics express·2025
Same author

Multifocal near-eye display with a vari-focal lens and adjustable aperture.

Optics express·2025

Related Experiment Video

Updated: Nov 23, 2025

Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects
10:16

Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects

Published on: February 8, 2014

12.5K

Quality enhancement of binary-encoded amplitude holograms by using error diffusion.

Kyosik Min, Jae-Hyeung Park

    Optics Express
    |December 31, 2020
    PubMed
    Summary
    This summary is machine-generated.

    This study introduces a new hologram encoding technique using error diffusion for digital micro-mirror devices. This method improves 3D holographic display image quality by reducing noise and enhancing reconstruction.

    More Related Videos

    Quantifying Microorganisms at Low Concentrations Using Digital Holographic Microscopy DHM
    07:27

    Quantifying Microorganisms at Low Concentrations Using Digital Holographic Microscopy DHM

    Published on: November 1, 2017

    10.7K
    Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
    08:39

    Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator

    Published on: January 28, 2019

    10.1K

    Related Experiment Videos

    Last Updated: Nov 23, 2025

    Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects
    10:16

    Digital Inline Holographic Microscopy DIHM of Weakly-scattering Subjects

    Published on: February 8, 2014

    12.5K
    Quantifying Microorganisms at Low Concentrations Using Digital Holographic Microscopy DHM
    07:27

    Quantifying Microorganisms at Low Concentrations Using Digital Holographic Microscopy DHM

    Published on: November 1, 2017

    10.7K
    Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator
    08:39

    Shaping the Amplitude and Phase of Laser Beams by Using a Phase-only Spatial Light Modulator

    Published on: January 28, 2019

    10.1K

    Area of Science:

    • Optics and Photonics
    • Digital Imaging
    • Holography

    Background:

    • Digital micro-mirror devices (DMDs) are widely used spatial light modulators in holographic 3D displays.
    • DMDs are limited to binary amplitude modulation, which degrades reconstruction image quality.
    • Existing methods struggle with noise and image fidelity in holographic displays.

    Purpose of the Study:

    • To propose a novel binary hologram encoding technique for DMDs.
    • To enhance the reconstruction image quality in holographic 3D displays.
    • To reduce binarization noise and improve signal energy concentration.

    Main Methods:

    • Developed a novel binary hologram encoding technique applying error diffusion algorithm.
    • Incorporated carrier wave considerations into the error diffusion weights.
    • Utilized time-multiplexing in conjunction with the proposed encoding technique.

    Main Results:

    • The proposed error diffusion weights effectively suppress binarization noise around the hologram carrier wave.
    • Enhanced signal energy concentration around the carrier wave.
    • Achieved speckless, enhanced-quality 3D reconstruction with a shallow depth of focus.

    Conclusions:

    • The novel binary hologram encoding technique significantly improves holographic 3D display image quality.
    • The method effectively addresses the limitations of binary amplitude modulation in DMDs.
    • Validated through simulations and optical experiments, demonstrating practical applicability.