Corrected Intraocular Pressure Variability with Central Corneal Thickness Measurement
Mohamed Attia Ali Ahmed1, Ahmed Shawkat Abdelhalim1
1Ophthalmology Department, Faculty of Medicine, Minia University, Minia, Egypt.
Clinical Ophthalmology (Auckland, N.Z.)
|December 31, 2020
Summary
Intraocular pressure (IOP) is linked to central corneal thickness (CCT), regardless of measurement method. Corrected IOP shows a negative correlation with CCT, highlighting the importance of thickness in pressure readings.
Area of Science:
- Ophthalmology
- Biometry
- Corneal Physiology
Background:
- Intraocular pressure (IOP) is a key factor in glaucoma diagnosis.
- Central corneal thickness (CCT) is known to influence IOP measurements.
- Variability in CCT measurement techniques may affect IOP assessment.
Purpose of the Study:
- To compare intraocular pressure (IOP) variability using central corneal thickness (CCT) measurements from ultrasonic and optical methods.
- To evaluate the correlation between measured IOP and CCT-corrected IOP (IOPcc) obtained via different CCT measurement tools.
Main Methods:
- 46 healthy subjects underwent CCT measurement using ultrasonic pachymetry (CCT1) and anterior-segment optical coherence tomography (AS-OCT) (CCT2).
- Intraocular pressure (IOP) was measured using Goldmann applanation tonometry (GAT).
- Statistical analysis was performed to compare IOP values and assess correlations between CCT and IOPcc.
Main Results:
- No significant differences were found in IOP or CCT-corrected IOP (IOPcc1, IOPcc2) between the measurement methods.
- A significant negative correlation was observed between corrected IOP values and CCT measured by both ultrasonic and optical tools (P=0.004 and P=0.001, respectively).
Conclusions:
- Intraocular pressure is dependent on and positively correlated with central corneal thickness.
- The method used for CCT measurement (ultrasonic vs. optical) did not significantly impact the observed correlations.
- Corrected intraocular pressure demonstrates a negative correlation with both ultrasonically and optically measured central corneal thickness.
Related Concept Videos
Angle Closure Glaucoma: Treatment
958
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
958
Open Angle Glaucoma: Treatment
832
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
832
Glaucoma: Overview
1.1K
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.1K