Related Experiment Video
Updated: Nov 23, 2025

Removal of Trace Elements by Cupric Oxide Nanoparticles from Uranium In Situ Recovery Bleed Water and Its Effect on Cell Viability
Published on: June 21, 2015
Accumulation of vanadium and arsenic by cast iron pipe scales under drinking water conditions: A batch study
Nan He1, Yimei Tian1, Chuntong Liu2
1School of Environmental Science and Engineering, Tianjin University, Tianjin, 300350, China.
Abstract:
Metal pollutants accumulation in the scales of drinking water distribution systems presents a potential threat to water quality. Therefore, a study was carried out on the accumulation of V(V) and As(V) by cast iron pipe scales. The accumulation of V(V) and As(V) by scales and the effects of scale dosage, pH, temperature, and anion content on the accumulation process were assessed. Results showed that scales could rapidly accumulate V(V) and As(V), with maximum accumulation amounts of 3.94 mg/g and 3.90 mg/g, respectively. An increase in pH (from 3.0 to 9.0) and sulfate concentration (from 0 to 250 mg/L) decreased V(V) and As(V) accumulation by scales. Increased chloride ion concentrations (from 0 to 250 mg/L) reduced the amount of As(V) accumulated, while increasing the amount of V(V) accumulated. The V(V) and As(V) accumulation kinetics were well described by the Elovich model, with thermodynamic and accumulation isotherms showing that the accumulation process occurred via an entropic endothermic reaction. The mechanisms of accumulation of V(V) and As(V) by the scales include surface complexation, ligand exchange, electrostatic attraction and repulsion, and competitive adsorption.