Related Experiment Video
Updated: Nov 23, 2025

X-ray Dose Reduction through Adaptive Exposure in Fluoroscopic Imaging
Published on: September 11, 2011
Accident and emergency radiography: A comparison of radiographer commenting and 'red dotting'
1Division of Radiography, University of Bradford, School of Health Studies, Trinity Road, Bradford, West Yorkshire BD5 0BB, United Kingdom.
Purpose:
The College of Radiographers has called for 'Red Dot' schemes to evolve and has recommended the development of radiographer commenting. The implementation of a radiographer comment scheme assumes that radiographers previously participating in 'red dot' schemes have been accurately recognising radiographic abnormalities and are, therefore, able to comment upon, and describe, such radiographic appearances. Research evidence to support such an assumption is sparse. This study compares the ability of radiographers attending a short course on musculoskeletal trauma to 'red dot' and comment on A&E radiographic appearances.
Methods:
This study adopted a pre-test, post-test approach. One hundred and twenty one radiographers attending a short course on musculoskeletal trauma (Bradford Red Dot Course) were invited to undertake an assessment of their ability to recognise ('red dot') and describe (comment upon) radiographic abnormalities at the start and end of the short course.
Results:
One hundred and fifteen radiographers (n=115/121; 95.0%) completed both the pre- and post-training assessments. Post-training mean scores per case improved on average by 9.8% [p=0.012; 95% CI: 2.4, 17.1] for 'red dots' and 12.7% [p=0.007; 95% CI: 3.8, 21.5] for commenting. However, the difference between mean 'red dot' and commenting scores remained similar with mean radiographer comment scores being 13.7% less than mean 'red dot' scores pre-training and 10.8% less post-training.
Conclusions:
The results of this study indicate that the accuracy of radiographer comments was significantly reduced when compared to the accuracy of 'red dots' for the same radiographic images. The clinical significance of these findings for departments wanting to move from a 'red dot' system to a radiographer commenting scheme is that without appropriate training and audit, the quality of service and assistance to the A&E department could be significantly reduced.
More Related Videos
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Related Concept Videos
X-ray Imaging
Radiological Investigation I: X-ray and CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...