Accuracy of a battery-powered portable capnometer in premature infants
Eiji Hirakawa1,2, Satoshi Ibara3
1Department of Neonatology, Nagasaki Harbor Medical Center, Nagasaki, Japan. hirakawaeiji@gmail.com.
Abstract:
Carbon dioxide measurement is useful for confirmation of successful tracheal intubation and ensuring adequate ventilation. There are two types of CO2 detectors, i.e., single-use-only colorimetric devices and capnometers. Although portable capnometers are widely used for resuscitation, there have been no reports regarding their clinical utility in neonates. The correspondence between end-tidal CO2 (PetCO2) level determined using a battery-powered portable capnometer and arterial CO2 (PaCO2) was investigated using paired data obtained simultaneously from 26 neonates weighing 1262 ± 589 g at examination on mechanical ventilation. PetCO2 level and PaCO2 showed a strong correlation (r = 0.839, P < 0.001), and the correlation equation was: PetCO2 = 0.8 × PaCO2 + 1.1. Therefore, PetCO2 readings obtained with a battery-powered portable capnometer were likely to be underestimated. This became more pronounced with decreasing infant body weight at examination as the net difference in measurements of PaCO2 and PetCO2 was significantly positively correlated with infant body weight at examination (r = 0.451, P < 0.001). The observations presented here may be helpful in the use of battery-powered portable capnometers in neonates requiring controlled ventilation with tracheal intubation.
More Related Videos
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Uncertainty in Measurement: Reading Instruments
Potentiometer
Suppose the emf of a battery needs to be measured. If the battery is directly connected to a standard voltmeter, the measured quantity is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation: