Related Experiment Video
Updated: Nov 23, 2025

Collecting Saliva and Measuring Salivary Cortisol and Alpha-amylase in Frail Community Residing Older Adults via Family Caregivers
Published on: December 18, 2013
Evaluation of variation of saliva iodine and recommendations for sample size and sampling time: Implications for
Wenxing Guo1, Shuyao Dong1, Ya Jin1
1Department of Nutrition and Food Hygiene, School of Public Health, Tianjin Medical University, Tianjin, China.
Background:
Saliva iodine concentration (SIC) has been found to be a good indicator of iodine nutritional status. However, limited information is available regarding saliva iodine characteristics.
Aims:
The study aimed to evaluate intra-day, intra-individual, and population SIC variation in order to provide information on optimal sample size and sampling time for assessing iodine nutritional status.
Methods:
Twenty-nine healthy school-aged students were recruited. Iodine intake from diet and water, and iodine excretion through urine and feces were assessed over a three-day period. Saliva samples were collected six times a day.
Results:
Diurnal variations were observed in SIC corresponding to iodine intake. The mean CV in SIC was lower than that for 24-hour urinary iodine concentration (24-h UIC) and 24-hour urinary iodine excretion (24-h UIE) not only at the individual level (42.73% vs. 47.71% and 49.69%) but also at the population level (71.29% vs. 100.43% and 72.49%). The number of saliva samples needed to estimate the iodine level with 95% CI within precision ranges of ±10%, ±20% was 55, 14 in an individual, and 180, 45 in a population. There was a good correlation between post-lunch SIC and total daily iodine intake.
Conclusions:
Saliva iodine has utility for evaluating the recent iodine nutrition of individuals and populations. The variation in SIC was lower than that for 24-h UIC and 24-h UIE. Saliva may be preferred over urine because of its ease of collection. Fourteen samples are needed to assess individual iodine status and forty-five saliva samples for assessment of population iodine status with reasonable precision. We recommend that saliva samples be collected after 14:00 in a day.
More Related Videos
09:08Developing a Salivary Antibody Multiplex Immunoassay to Measure Human Exposure to Environmental Pathogens
Published on: September 12, 2016
07:32Use of Galvanic Skin Responses, Salivary Biomarkers, and Self-reports to Assess Undergraduate Student Performance During a Laboratory Exam Activity
Published on: February 10, 2016
Related Concept Videos
Redox Titration: Iodimetry and Iodometry
Inflammatory Bowel Disease III: Diagnostic Studies and Management I-Nutritional Therapy
Diagnostic studies
A colonoscopy is the definitive screening test, distinguishing ulcerative colitis from other colon diseases with similar symptoms. During a colonoscopy test, inflamed mucosa with exudate ulcerations can be observed, and biopsies are taken to determine the histologic characteristics of the...