Evaluation of different approaches to applying the standard additions calibration method
John T Sloop1, Daniel A Gonçalves2, Logan M O'Brien1
1Department of Chemistry, Wake Forest University, Salem Hall, Box 7486, Winston-Salem, NC, 27109, USA.
Abstract:
The extrapolation approach, traditionally used with standard additions (SA), is compared with the alternative strategies of interpolation, reversed-axis, and normalization. The interpolation approach is based on employing twice the analytical signal recorded for the sample (ysam) to determine an unknown analyte concentration. In the reversed-axis strategy, x- and y-axes are swapped when building the SA calibration plot to facilitate uncertainty estimation. A new strategy, based on signal normalization using ysam, is also described and compared to the other approaches. Results from 3 instrumental methods, 396 sample replicates, 16 analytes, and 2 certified reference materials are included in this study. For most applications, all four SA approaches provide statistically similar trueness and precision. However, extrapolation and reversed-axis provide more consistent values (within narrower ranges) than the other strategies when employing inductively coupled plasma optical emission spectrometry (ICP OES). On the other hand, normalization provides better trueness for the less robust method of microwave-induced plasma OES (MIP OES), as it is capable of minimizing systematic errors associated with different points of the calibration curve. Normalization is particularly useful for quickly processing data, without the need for inspecting each individual calibration plot to identify outlying points. Reversed-axis and normalization are the most adequate approaches for SA applications involving MIP OES and ICP-based methods. In addition to providing similar accuracies to the traditional extrapolation approach, these strategies present the advantage of a simple uncertainty estimation, which can be easily calculated using commonly available software such as Microsoft Excel and R.
More Related Videos
10:29Calibrated Passive Sampling - Multi-plot Field Measurements of NH3 Emissions with a Combination of Dynamic Tube Method and Passive Samplers
Published on: March 21, 2016
11:18Use of Atomic Force Microscopy to Measure Mechanical Properties and Turgor Pressure of Plant Cells and Plant Tissues
Published on: July 15, 2019
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...
Distance Corrections
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Correlation Coefficient
Uncertainty in Measurement: Reading Instruments